← Florida

Tap water quality report

Sjcu-Ponte Vedra Ws

EPA monitoring tested this supplier for 99 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

99
contaminants tested
13
detected
15,565
people served
13
health-based violations
Water source
Ground water
Ownership
Private
Counties served
St. Johns

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

13
health-based violations
46
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2011-11-01 → 2011-11-30
MCL Health-based Archived 2008-07-01 → 2008-07-31
MCL Health-based Archived 2008-07-01 → 2008-07-31
MCL Health-based Archived 2008-07-01 → 2008-07-31
MCL Health-based Archived 2003-11-01 → 2003-11-30
MCL Health-based Archived 1997-10-01 → 1997-10-31
MCL Health-based Archived 1996-06-01 → 1996-06-30
MCL Health-based Archived 1995-04-01 → 1995-04-30
MCL Health-based Archived 1993-09-01 → 1993-09-30
MCL Health-based Archived 1992-11-01 → 1992-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
72.344 µg/L 90%
of the EPA limit 80 µg/L
worst single sample: 81.97 µg/L
72/72 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
28.8175 µg/L 48%
of the EPA limit 60 µg/L
worst single sample: 44.65 µg/L
72/72 SYR4 2012–2019
Nitrate
45.83 µg/L 0.5%
of the EPA limit 10000 µg/L
worst single sample: 46.4 µg/L
24/32 SYR4 2012–2019
Lead
0.00090 mg/L 6%
of the EPA limit 0.0150 mg/L
15/15 LCR 2024
Fluoride
720 µg/L 18%
of the EPA limit 4000 µg/L
8/8 SYR4 2014–2017
Barium
26 µg/L 1.3%
of the EPA limit 2000 µg/L
4/4 SYR4 2014–2017
Copper
14.6 µg/L 1.1%
of the EPA limit 1300 µg/L
worst single sample: 15 µg/L
3/3 SYR4 2014–2017
Lead
0.3950 µg/L 2.6%
of the EPA limit 15 µg/L
worst single sample: 0.4000 µg/L
2/4 SYR4 2014–2017
Nitrite
7.89 µg/L 0.8%
of the EPA limit 1000 µg/L
worst single sample: 7.9 µg/L
2/16 SYR4 2012–2019
Antimony, Total
0.4000 µg/L 6.7%
of the EPA limit 6 µg/L
1/4 SYR4 2014–2017
Cadmium
0.2000 µg/L 4%
of the EPA limit 5 µg/L
1/4 SYR4 2014–2017
Selenium
25 µg/L 50%
of the EPA limit 50 µg/L
1/4 SYR4 2014–2017
Lithium
10 µg/L
No EPA limit set
1/4 UCMR-5 2024
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MR. NEAL SHINKRE
Phone
904-209-2703

Frequently asked questions about Sjcu-Ponte Vedra Ws

Is Sjcu-Ponte Vedra Ws tap water safe to drink?

EPA monitoring detected 13 contaminants in Sjcu-Ponte Vedra Ws's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sjcu-Ponte Vedra Ws's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Nitrate, Lead, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Sjcu-Ponte Vedra Ws serve?

Sjcu-Ponte Vedra Ws reports serving 15,565 people in Florida, per its EPA record.

Has Sjcu-Ponte Vedra Ws had any water quality violations?

The EPA has 46 violations on file for Sjcu-Ponte Vedra Ws, of which 13 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.