← Connecticut

Tap water quality report

Aquarion-Scodon

EPA monitoring tested this supplier for 80 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
18
detected
130
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Fairfield

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
18
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2016-01-01 → 2016-03-31
MCL Health-based Resolved 2016-01-01 → 2016-03-31
MCL Health-based Resolved 2016-01-01 → 2016-03-31
MCL Health-based Resolved 2016-01-01 → 2016-03-31
MR Monitoring Resolved 2021-12-30
Other Monitoring Resolved 2018-07-01
Other Monitoring Resolved 2018-07-01
Other Monitoring Resolved 2016-03-19
Other Monitoring Resolved 2010-07-01
Other Monitoring Resolved 2010-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
270 µg/L 21%
of the EPA limit 1300 µg/L
70/74 SYR4 2012–2019
Lead
19 µg/L 127%
of the EPA limit, in the worst sample — 15 µg/L
46/74 SYR4 2012–2019
Nitrate
942 µg/L 9.4%
of the EPA limit 10000 µg/L
28/28 SYR4 2012–2019
Lead
0.0028 mg/L 19%
of the EPA limit 0.0150 mg/L
16/16 LCR 2027
Nitrate-Nitrite
942 µg/L 9.4%
of the EPA limit 10000 µg/L
14/14 SYR4 2012–2019
Bromodichloromethane
3 µg/L
No EPA limit set
10/17 SYR4 2013–2019
Dibromochloromethane
3 µg/L
No EPA limit set
10/17 SYR4 2013–2019
Combined Radium (-226 And -228)
3.5 pCi/L 70%
of the EPA limit 5 pCi/L
9/13 SYR4 2013–2019
Bromoform
2.1 µg/L
No EPA limit set
8/17 SYR4 2013–2019
Barium
56 µg/L 2.8%
of the EPA limit 2000 µg/L
7/7 SYR4 2012–2019
Fluoride
230 µg/L 5.8%
of the EPA limit 4000 µg/L
7/7 SYR4 2012–2019
Chloroform
3 µg/L
No EPA limit set
6/17 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
4.6 pCi/L 31%
of the EPA limit 15 pCi/L
6/13 SYR4 2013–2019
Combined Uranium
1.2 µg/L 4%
of the EPA limit 30 µg/L
5/13 SYR4 2013–2019
Dibromoacetic Acid
1 µg/L
No EPA limit set
2/2 SYR4 2018–2019
Dichloroacetic Acid
1 µg/L
No EPA limit set
2/2 SYR4 2018–2019
TTHM
9 µg/L 11%
of the EPA limit 80 µg/L
2/2 SYR4 2018–2019
Total Haloacetic Acids (HAA5)
2 µg/L 3.3%
of the EPA limit 60 µg/L
2/2 SYR4 2018–2019
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ULRICH, ROBERT J.
Phone
203-926-4320
Email
rulrich@aquarionwater.com

Frequently asked questions about Aquarion-Scodon

Is Aquarion-Scodon tap water safe to drink?

EPA monitoring detected 18 contaminants in Aquarion-Scodon's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Aquarion-Scodon's water?

EPA monitoring detected Copper, Lead, Nitrate, Lead, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Aquarion-Scodon serve?

Aquarion-Scodon reports serving 130 people in Connecticut, per its EPA record.

Has Aquarion-Scodon had any water quality violations?

The EPA has 18 violations on file for Aquarion-Scodon, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.