← Connecticut

Tap water quality report

Aquarion-Carmen Hill

EPA monitoring tested this supplier for 81 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
20
detected
322
people served
30
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Litchfield

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

30
health-based violations
195
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2011-09-01 → 2011-09-30
MCL Health-based Resolved 2011-09-01 → 2011-09-30
MCL Health-based Resolved 2011-09-01 → 2011-09-30
MCL Health-based Resolved 2011-09-01 → 2011-09-30
MCL Health-based Resolved 1998-12-01 → 1998-12-31
MCL Health-based Resolved 1998-12-01 → 1998-12-31
MCL Health-based Resolved 1998-12-01 → 1998-12-31
MCL Health-based Resolved 1998-12-01 → 1998-12-31
MCL Health-based Resolved 1998-12-01 → 1998-12-31
MCL Health-based Resolved 1998-12-01 → 1998-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2860 µg/L 29%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Copper
1030 µg/L 79%
of the EPA limit 1300 µg/L
15/15 SYR4 2012–2018
Combined Radium (-226 And -228)
3.1 pCi/L 62%
of the EPA limit 5 pCi/L
13/17 SYR4 2013–2019
Bromodichloromethane
4.6 µg/L
No EPA limit set
12/12 SYR4 2012–2019
Dibromochloromethane
7.2 µg/L
No EPA limit set
12/12 SYR4 2012–2019
Chloroform
2.6 µg/L
No EPA limit set
11/12 SYR4 2012–2019
Lead
0.0013 mg/L 8.7%
of the EPA limit 0.0150 mg/L
11/11 LCR 2025
Combined Uranium
48 µg/L 160%
of the EPA limit, in the worst sample — 30 µg/L
10/20 SYR4 2013–2019
Lead
20 µg/L 133%
of the EPA limit, in the worst sample — 15 µg/L
10/15 SYR4 2012–2018
Bromoform
3.2 µg/L
No EPA limit set
9/12 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
15.2 pCi/L 101%
of the EPA limit, in the worst sample — 15 pCi/L
9/17 SYR4 2013–2019
Nitrate-Nitrite
2860 µg/L 29%
of the EPA limit 10000 µg/L
8/8 SYR4 2012–2019
TTHM
17.6 µg/L 22%
of the EPA limit 80 µg/L
8/8 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
5 µg/L 8.3%
of the EPA limit 60 µg/L
8/8 SYR4 2012–2019
Dibromoacetic Acid
2.4 µg/L
No EPA limit set
7/8 SYR4 2012–2019
Dichloroacetic Acid
6 µg/L
No EPA limit set
6/8 SYR4 2012–2019
Barium
97 µg/L 4.9%
of the EPA limit 2000 µg/L
3/3 SYR4 2012–2018
Fluoride
160 µg/L 4%
of the EPA limit 4000 µg/L
3/3 SYR4 2012–2018
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2018
Trichloroacetic Acid
1.1 µg/L
No EPA limit set
1/8 SYR4 2012–2019
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneGlyphosateGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ULRICH, ROBERT J.
Phone
203-926-4320
Email
rulrich@aquarionwater.com

Frequently asked questions about Aquarion-Carmen Hill

Is Aquarion-Carmen Hill tap water safe to drink?

EPA monitoring detected 20 contaminants in Aquarion-Carmen Hill's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Aquarion-Carmen Hill's water?

EPA monitoring detected Nitrate, Copper, Combined Radium (-226 And -228), Bromodichloromethane, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Aquarion-Carmen Hill serve?

Aquarion-Carmen Hill reports serving 322 people in Connecticut, per its EPA record.

Has Aquarion-Carmen Hill had any water quality violations?

The EPA has 195 violations on file for Aquarion-Carmen Hill, of which 30 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.