← Connecticut

Tap water quality report

Ctwc - London Park Division

EPA monitoring tested this supplier for 80 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
15
detected
221
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Tolland

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
21
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2000-11-01 → 2000-11-30
MCL Health-based Resolved 2000-11-01 → 2000-11-30
MCL Health-based Resolved 2000-11-01 → 2000-11-30
MCL Health-based Resolved 2000-11-01 → 2000-11-30
Other Monitoring Resolved 2017-06-25
Other Monitoring Resolved 2006-07-28
Other Monitoring Resolved 2006-07-28
Other Monitoring Resolved 2005-08-10
Other Monitoring Resolved 2005-08-10
MR Monitoring Resolved 2004-01-01 → 2004-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
434 µg/L 33%
of the EPA limit 1300 µg/L
111/111 SYR4 2012–2019
Lead
150 µg/L 1000%
of the EPA limit, in the worst sample — 15 µg/L
29/111 SYR4 2012–2019
Nitrate
5660 µg/L 57%
of the EPA limit 10000 µg/L
28/28 SYR4 2012–2019
Lead
0.0011 mg/L 7.3%
of the EPA limit 0.0150 mg/L
22/22 LCR 2025
Nitrate-Nitrite
5660 µg/L 57%
of the EPA limit 10000 µg/L
10/10 SYR4 2012–2019
Bromodichloromethane
5.4 µg/L
No EPA limit set
8/9 SYR4 2012–2019
Bromoform
10 µg/L
No EPA limit set
8/9 SYR4 2012–2019
Dibromochloromethane
11 µg/L
No EPA limit set
8/9 SYR4 2012–2019
Chloroform
2.6 µg/L
No EPA limit set
6/9 SYR4 2012–2019
TTHM
28 µg/L 35%
of the EPA limit 80 µg/L
6/6 SYR4 2015–2019
Dibromoacetic Acid
3.4 µg/L
No EPA limit set
5/6 SYR4 2015–2019
Total Haloacetic Acids (HAA5)
3.4 µg/L 5.7%
of the EPA limit 60 µg/L
5/6 SYR4 2015–2019
Barium
50 µg/L 2.5%
of the EPA limit 2000 µg/L
2/3 SYR4 2012–2018
Dichloroacetic Acid
0.7000 µg/L
No EPA limit set
1/6 SYR4 2015–2019
Hexachlorocyclopentadiene
0.0290 µg/L 0.1%
of the EPA limit 50 µg/L
1/3 SYR4 2013–2019
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndrinEthylbenzeneFluorideGlyphosateGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LOWRY, PAUL C.
Phone
860-944-9655
Email
ctwcdphadmin@ctwater.com

Frequently asked questions about Ctwc - London Park Division

Is Ctwc - London Park Division tap water safe to drink?

EPA monitoring detected 15 contaminants in Ctwc - London Park Division's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ctwc - London Park Division's water?

EPA monitoring detected Copper, Lead, Nitrate, Lead, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Ctwc - London Park Division serve?

Ctwc - London Park Division reports serving 221 people in Connecticut, per its EPA record.

Has Ctwc - London Park Division had any water quality violations?

The EPA has 21 violations on file for Ctwc - London Park Division, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.