Tap water quality report

Freeman Creek

EPA monitoring tested this supplier for 69 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
13
detected
88
people served
38
health-based violations
Water source
Ground water under surface influence
Ownership
Private
Counties served
La Plata

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

38
health-based violations
491
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2023-02-01 → 2023-02-28
TT Health-based Resolved 2023-02-01 → 2023-02-28
TT Health-based Resolved 2023-02-01 → 2023-02-28
TT Health-based Resolved 2023-02-01 → 2023-02-28
TT Health-based Resolved 2022-12-01 → 2022-12-31
TT Health-based Resolved 2022-12-01 → 2022-12-31
TT Health-based Resolved 2022-12-01 → 2022-12-31
TT Health-based Resolved 2022-12-01 → 2022-12-31
TT Health-based Resolved 2021-02-01 → 2021-02-28
TT Health-based Resolved 2021-02-01 → 2021-02-28

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
575 µg/L 5.8%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Nitrate-Nitrite
538.6 µg/L 5.4%
of the EPA limit 10000 µg/L
worst single sample: 575 µg/L
8/8 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
6/6 LCR 2025
Barium
159.65 µg/L 8%
of the EPA limit 2000 µg/L
worst single sample: 161 µg/L
4/4 SYR4 2019
Combined Uranium
3.07 µg/L 10%
of the EPA limit 30 µg/L
worst single sample: 3.1 µg/L
4/4 SYR4 2019
Fluoride
151.8 µg/L 3.8%
of the EPA limit 4000 µg/L
worst single sample: 153 µg/L
4/4 SYR4 2019
Gross Alpha, Excl. Radon And U
1.86365 pCi/L 12%
of the EPA limit 15 pCi/L
worst single sample: 2 pCi/L
4/4 SYR4 2019
Gross Beta Particle Activity
5.275 pCi/L
No EPA limit set
worst single sample: 5.4 pCi/L
2/2 SYR4 2019
Chlorobenzene
25.6 µg/L 26%
of the EPA limit 100 µg/L
1/4 SYR4 2019
Chromium
1.1 µg/L 1.1%
of the EPA limit 100 µg/L
1/4 SYR4 2019
Combined Radium (-226 And -228)
0.5600 pCi/L 11%
of the EPA limit 5 pCi/L
1/4 SYR4 2019
TTHM
2.36 µg/L 2.9%
of the EPA limit 80 µg/L
1/1 SYR4 2019
O-Dichlorobenzene
2.8 µg/L 0.5%
of the EPA limit 600 µg/L
1/4 SYR4 2019
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WALB, STEVE
Phone
602-489-1184
Email
SNWALB@YAHOO.COM

Frequently asked questions about Freeman Creek

Is Freeman Creek tap water safe to drink?

EPA monitoring detected 13 contaminants in Freeman Creek's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Freeman Creek's water?

EPA monitoring detected Nitrate, Nitrate-Nitrite, Lead, Barium, Combined Uranium, and others. The full list with the level and data source for each is above.

How many people does Freeman Creek serve?

Freeman Creek reports serving 88 people in Colorado, per its EPA record.

Has Freeman Creek had any water quality violations?

The EPA has 491 violations on file for Freeman Creek, of which 38 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.