← Colorado

Tap water quality report

Westwood Lakes Wd

EPA monitoring tested this supplier for 78 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
20
detected
450
people served
4
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Teller

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
248
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2018-04-01
TT Health-based Resolved 2018-04-01
TT Health-based Resolved 2018-04-01
TT Health-based Resolved 2018-04-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
Other Monitoring Resolved 2024-07-01
MR Monitoring Resolved 2020-07-01
MR Monitoring Resolved 2020-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
19/19 LCR 2023
Nitrate
2000 µg/L 20%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
TTHM
9.61 µg/L 12%
of the EPA limit 80 µg/L
6/6 SYR4 2012–2018
Xylenes, Total
1.65 µg/L 0%
of the EPA limit 10000 µg/L
5/8 SYR4 2012–2019
Bromodichloromethane
1.8 µg/L
No EPA limit set
4/4 SYR4 2016–2018
Bromoform
1.7 µg/L
No EPA limit set
4/4 SYR4 2016–2018
Dibromochloromethane
3 µg/L
No EPA limit set
4/4 SYR4 2016–2018
Barium
83 µg/L 4.2%
of the EPA limit 2000 µg/L
3/3 SYR4 2013–2019
Chloroform
0.7200 µg/L
No EPA limit set
3/4 SYR4 2016–2018
Fluoride
1600 µg/L 40%
of the EPA limit 4000 µg/L
3/3 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
2.3 µg/L 3.8%
of the EPA limit 60 µg/L
3/3 SYR4 2012–2018
Combined Radium (-226 And -228)
1.9 pCi/L 38%
of the EPA limit 5 pCi/L
2/2 SYR4 2013–2019
Arsenic
2 µg/L 20%
of the EPA limit 10 µg/L
1/3 SYR4 2013–2019
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/3 SYR4 2013–2019
Combined Uranium
0.3700 µg/L 1.2%
of the EPA limit 30 µg/L
1/1 SYR4 2013
Dibromoacetic Acid
1.7 µg/L
No EPA limit set
1/1 SYR4 2018
Gross Alpha, Excl. Radon And U
1.2 pCi/L 8%
of the EPA limit 15 pCi/L
1/1 SYR4 2013
Gross Beta Particle Activity
2.8 pCi/L
No EPA limit set
1/1 SYR4 2013
Nitrate-Nitrite
1350 µg/L 14%
of the EPA limit 10000 µg/L
1/1 SYR4 2013
Selenium
2 µg/L 4%
of the EPA limit 50 µg/L
1/3 SYR4 2013–2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PARRISH, ELMO M
Email
yolanda522003@yahoo.com

Frequently asked questions about Westwood Lakes Wd

Is Westwood Lakes Wd tap water safe to drink?

EPA monitoring detected 20 contaminants in Westwood Lakes Wd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Westwood Lakes Wd's water?

EPA monitoring detected Lead, Nitrate, TTHM, Xylenes, Total, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Westwood Lakes Wd serve?

Westwood Lakes Wd reports serving 450 people in Colorado, per its EPA record.

Has Westwood Lakes Wd had any water quality violations?

The EPA has 248 violations on file for Westwood Lakes Wd, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.