← Colorado

Tap water quality report

Peak View Park Llc

EPA monitoring tested this supplier for 78 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
13
detected
106
people served
106
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Teller

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

106
health-based violations
371
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2023-02-01
TT Health-based Resolved 2023-02-01
TT Health-based Resolved 2023-02-01
TT Health-based Resolved 2023-02-01
MCL Health-based Resolved 2021-10-01 → 2021-12-31
MCL Health-based Resolved 2021-10-01 → 2021-12-31
MCL Health-based Resolved 2021-10-01 → 2021-12-31
MCL Health-based Resolved 2021-10-01 → 2021-12-31
MCL Health-based Resolved 2021-07-01 → 2021-09-30
MCL Health-based Resolved 2021-07-01 → 2021-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
400 µg/L 4%
of the EPA limit 10000 µg/L
20/20 SYR4 2017–2019
Combined Radium (-226 And -228)
15 pCi/L 300%
of the EPA limit, in the worst sample — 5 pCi/L
10/10 SYR4 2017–2019
Lead
0.00060 mg/L 4%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
Fluoride
2230 µg/L 56%
of the EPA limit 4000 µg/L
5/5 SYR4 2017–2018
Barium
170 µg/L 8.5%
of the EPA limit 2000 µg/L
4/4 SYR4 2017–2018
Combined Uranium
2.1 µg/L 7%
of the EPA limit 30 µg/L
4/4 SYR4 2017–2018
Gross Alpha, Excl. Radon And U
13.66 pCi/L 91%
of the EPA limit 15 pCi/L
4/4 SYR4 2017–2018
Selenium
1.6 µg/L 3.2%
of the EPA limit 50 µg/L
3/4 SYR4 2017–2018
Nitrate-Nitrite
360 µg/L 3.6%
of the EPA limit 10000 µg/L
2/2 SYR4 2017–2018
Beryllium, Total
0.5900 µg/L 15%
of the EPA limit 4 µg/L
1/4 SYR4 2017–2018
Di(2-ethylhexyl) Phthalate
0.8600 µg/L 14%
of the EPA limit 6 µg/L
1/5 SYR4 2017–2019
Gross Beta Particle Activity
13 pCi/L
No EPA limit set
1/1 SYR4 2018
Toluene
0.8000 µg/L 0.1%
of the EPA limit 1000 µg/L
1/6 SYR4 2017–2019
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBromodichloromethaneBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LABARRE, PETE
Phone
719-761-6741
Email
plabarre@rareearthdev.com

Frequently asked questions about Peak View Park Llc

Is Peak View Park Llc tap water safe to drink?

EPA monitoring detected 13 contaminants in Peak View Park Llc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Peak View Park Llc's water?

EPA monitoring detected Nitrate, Combined Radium (-226 And -228), Lead, Fluoride, Barium, and others. The full list with the level and data source for each is above.

How many people does Peak View Park Llc serve?

Peak View Park Llc reports serving 106 people in Colorado, per its EPA record.

Has Peak View Park Llc had any water quality violations?

The EPA has 371 violations on file for Peak View Park Llc, of which 106 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.