← Colorado

Tap water quality report

Copper Mountain Consolidated Md

EPA monitoring tested this supplier for 108 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
22
detected
5,785
people served
3
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Summit

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
6
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2002-04-01 → 2002-04-30
MCL Health-based Resolved 2002-04-01 → 2002-04-30
MCL Health-based Resolved 2002-04-01 → 2002-04-30
MR Monitoring Resolved 2020-01-01
MR Monitoring Resolved 2020-01-01
MR Monitoring Resolved 2020-01-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
550 µg/L 5.5%
of the EPA limit 10000 µg/L
46/50 SYR4 2012–2019
Lead
0.0050 mg/L 33%
of the EPA limit 0.0150 mg/L
22/22 LCR 2023
TTHM
22.6 µg/L 28%
of the EPA limit 80 µg/L
16/18 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
12.6 µg/L 21%
of the EPA limit 60 µg/L
14/17 SYR4 2012–2019
Barium
290 µg/L 14%
of the EPA limit 2000 µg/L
13/13 SYR4 2012–2019
Combined Uranium
3 µg/L 10%
of the EPA limit 30 µg/L
11/11 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
2.36 pCi/L 16%
of the EPA limit 15 pCi/L
11/11 SYR4 2012–2019
Bromodichloromethane
7.1 µg/L
No EPA limit set
10/14 SYR4 2012–2019
Dibromochloromethane
5.2 µg/L
No EPA limit set
10/14 SYR4 2012–2019
Chloroform
9.4 µg/L
No EPA limit set
9/14 SYR4 2012–2019
Combined Radium (-226 And -228)
2.1 pCi/L 42%
of the EPA limit 5 pCi/L
8/8 SYR4 2012–2019
Bromoform
1.1 µg/L
No EPA limit set
7/14 SYR4 2012–2019
Dibromoacetic Acid
1.7 µg/L
No EPA limit set
5/11 SYR4 2015–2019
Nitrate-Nitrite
550 µg/L 5.5%
of the EPA limit 10000 µg/L
5/5 SYR4 2012–2019
Selenium
1 µg/L 2%
of the EPA limit 50 µg/L
5/13 SYR4 2012–2019
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
4/13 SYR4 2012–2019
Monochloroacetic Acid
5.4 µg/L
No EPA limit set
3/11 SYR4 2015–2019
Dichloroacetic Acid
3.6 µg/L
No EPA limit set
2/11 SYR4 2015–2019
Gross Beta Particle Activity
1.2 pCi/L
No EPA limit set
2/4 SYR4 2012–2019
Arsenic
2 µg/L 20%
of the EPA limit 10 µg/L
1/13 SYR4 2012–2019
Carbofuran
0.3200 µg/L 0.8%
of the EPA limit 40 µg/L
1/23 SYR4 2012–2019
Trichloroacetic Acid
3.1 µg/L
No EPA limit set
1/11 SYR4 2015–2019
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LANGE, CHELSEY
Phone
970-968-2537
Email
clange@coppermetro.org

Frequently asked questions about Copper Mountain Consolidated Md

Is Copper Mountain Consolidated Md tap water safe to drink?

EPA monitoring detected 22 contaminants in Copper Mountain Consolidated Md's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Copper Mountain Consolidated Md's water?

EPA monitoring detected Nitrate, Lead, TTHM, Total Haloacetic Acids (HAA5), Barium, and others. The full list with the level and data source for each is above.

How many people does Copper Mountain Consolidated Md serve?

Copper Mountain Consolidated Md reports serving 5,785 people in Colorado, per its EPA record.

Has Copper Mountain Consolidated Md had any water quality violations?

The EPA has 6 violations on file for Copper Mountain Consolidated Md, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.