← Colorado

Tap water quality report

Prairie View Ranch Wd

EPA monitoring tested this supplier for 77 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
15
detected
140
people served
21
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Morgan

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

21
health-based violations
532
violations on file
6
still open
ViolationTypeStatusPeriod
TT Health-based Addressed 2024-04-04
TT Health-based Addressed 2024-04-04
TT Health-based Addressed 2024-04-04
TT Health-based Addressed 2024-04-04
TT Health-based Addressed 2024-04-04
TT Health-based Addressed 2024-04-04
TT Health-based Resolved 2023-01-25
TT Health-based Resolved 2023-01-25
TT Health-based Resolved 2023-01-25
TT Health-based Resolved 2021-06-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
860 µg/L 8.6%
of the EPA limit 10000 µg/L
10/12 SYR4 2017–2019
Lead
0.00050 mg/L 3.3%
of the EPA limit 0.0150 mg/L
7/7 LCR 2023
Combined Radium (-226 And -228)
1.37 pCi/L 27%
of the EPA limit 5 pCi/L
worst single sample: 1.4 pCi/L
4/4 SYR4 2017–2018
Combined Uranium
21.55 µg/L 72%
of the EPA limit 30 µg/L
worst single sample: 22 µg/L
4/4 SYR4 2017–2018
Fluoride
667 µg/L 17%
of the EPA limit 4000 µg/L
worst single sample: 670 µg/L
4/5 SYR4 2017–2018
Selenium
47.7 µg/L 95%
of the EPA limit 50 µg/L
worst single sample: 48 µg/L
4/4 SYR4 2017–2018
Gross Alpha, Excl. Radon And U
4.412 pCi/L 29%
of the EPA limit 15 pCi/L
worst single sample: 4.63 pCi/L
2/4 SYR4 2017–2018
1,2-Dichloroethane
15.3 µg/L 306%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
1/5 SYR4 2017–2019
Bromoform
1.33 µg/L
No EPA limit set
1/1 SYR4 2017
Chloroform
0.9400 µg/L
No EPA limit set
1/1 SYR4 2017
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/4 SYR4 2017–2018
Dibromochloromethane
1.39 µg/L
No EPA limit set
1/1 SYR4 2017
Nitrate-Nitrite
800 µg/L 8%
of the EPA limit 10000 µg/L
1/1 SYR4 2017
Styrene
0.8000 µg/L 0.8%
of the EPA limit 100 µg/L
1/5 SYR4 2017–2019
TTHM
3.7 µg/L 4.6%
of the EPA limit 80 µg/L
1/1 SYR4 2017
62 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BELMONTE, SAM
Phone
303-483-5740
Email
DIRECTORS@PVRWD.ORG

Frequently asked questions about Prairie View Ranch Wd

Is Prairie View Ranch Wd tap water safe to drink?

EPA monitoring detected 15 contaminants in Prairie View Ranch Wd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Prairie View Ranch Wd's water?

EPA monitoring detected Nitrate, Lead, Combined Radium (-226 And -228), Combined Uranium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Prairie View Ranch Wd serve?

Prairie View Ranch Wd reports serving 140 people in Colorado, per its EPA record.

Has Prairie View Ranch Wd had any water quality violations?

The EPA has 532 violations on file for Prairie View Ranch Wd, of which 21 are health-based (a contaminant limit or required treatment was breached) and 6 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.