← Colorado

Tap water quality report

Heartwood Co Op Housing

EPA monitoring tested this supplier for 78 contaminants and detected 23. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
23
detected
60
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
La Plata

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
125
violations on file
2
still open
ViolationTypeStatusPeriod
Other Monitoring Unaddressed 2025-07-01
Other Monitoring Unaddressed 2025-07-01
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30
MR Monitoring Resolved 2025-07-01 → 2025-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
294 µg/L 2.9%
of the EPA limit 10000 µg/L
16/20 SYR4 2012–2019
Lead
0.0056 mg/L 37%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
TTHM
79.56 µg/L 99%
of the EPA limit 80 µg/L
worst single sample: 83.1 µg/L
13/13 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
35 µg/L 58%
of the EPA limit 60 µg/L
worst single sample: 41.2 µg/L
11/11 SYR4 2012–2019
Bromodichloromethane
19.79 µg/L
No EPA limit set
worst single sample: 20.6 µg/L
7/7 SYR4 2012–2019
Bromoform
14.99 µg/L
No EPA limit set
worst single sample: 17.9 µg/L
7/7 SYR4 2012–2019
Chloroform
14.07 µg/L
No EPA limit set
worst single sample: 14.7 µg/L
7/7 SYR4 2012–2019
Dibromochloromethane
25.82 µg/L
No EPA limit set
worst single sample: 27.2 µg/L
7/7 SYR4 2012–2019
Fluoride
2300 µg/L 57%
of the EPA limit 4000 µg/L
worst single sample: 2600 µg/L
6/6 SYR4 2014–2017
Barium
154.8 µg/L 7.7%
of the EPA limit 2000 µg/L
worst single sample: 156 µg/L
5/5 SYR4 2014–2018
Dibromoacetic Acid
7.46 µg/L
No EPA limit set
worst single sample: 7.7 µg/L
4/4 SYR4 2016–2019
Dichloroacetic Acid
5.595 µg/L
No EPA limit set
worst single sample: 5.7 µg/L
4/4 SYR4 2016–2019
Arsenic
1.96 µg/L 20%
of the EPA limit 10 µg/L
worst single sample: 2 µg/L
3/5 SYR4 2014–2018
Selenium
4.99 µg/L 10%
of the EPA limit 50 µg/L
worst single sample: 5 µg/L
3/5 SYR4 2014–2018
Trichloroacetic Acid
6.34 µg/L
No EPA limit set
worst single sample: 6.7 µg/L
3/4 SYR4 2016–2019
Xylenes, Total
3.05 µg/L 0%
of the EPA limit 10000 µg/L
worst single sample: 3.1 µg/L
3/12 SYR4 2012–2019
Combined Uranium
0.9370 µg/L 3.1%
of the EPA limit 30 µg/L
worst single sample: 0.9400 µg/L
2/2 SYR4 2015
Monobromoacetic Acid
1.49 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
2/4 SYR4 2016–2019
Nitrate-Nitrite
283.35 µg/L 2.8%
of the EPA limit 10000 µg/L
worst single sample: 294 µg/L
2/3 SYR4 2014–2015
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/5 SYR4 2014–2018
Gross Alpha, Excl. Radon And U
4.9702 pCi/L 33%
of the EPA limit 15 pCi/L
1/2 SYR4 2015
Monochloroacetic Acid
2.5 µg/L
No EPA limit set
1/4 SYR4 2016–2019
Pentachlorophenol
0.1000 µg/L 10%
of the EPA limit 1 µg/L
1/7 SYR4 2014–2019
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WALKER, BETH
Phone
970-799-8857
Email
bethwalker13@gmail.com

Frequently asked questions about Heartwood Co Op Housing

Is Heartwood Co Op Housing tap water safe to drink?

EPA monitoring detected 23 contaminants in Heartwood Co Op Housing's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Heartwood Co Op Housing's water?

EPA monitoring detected Nitrate, Lead, TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Heartwood Co Op Housing serve?

Heartwood Co Op Housing reports serving 60 people in Colorado, per its EPA record.

Has Heartwood Co Op Housing had any water quality violations?

The EPA has 125 violations on file for Heartwood Co Op Housing, of which 0 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.