← Colorado

Tap water quality report

Buckhorn Ranch Ws

EPA monitoring tested this supplier for 77 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
19
detected
205
people served
8
health-based violations
Water source
Ground water under surface influence
Ownership
Private
Counties served
Gunnison

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
74
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2025-02-01 → 2025-02-28
TT Health-based Resolved 2025-02-01 → 2025-02-28
TT Health-based Resolved 2025-02-01 → 2025-02-28
TT Health-based Resolved 2025-02-01 → 2025-02-28
TT Health-based Resolved 2019-10-02
TT Health-based Resolved 2019-10-02
TT Health-based Resolved 2019-10-02
TT Health-based Resolved 2019-10-02
MR Monitoring Resolved 2022-11-01 → 2022-11-30
MR Monitoring Resolved 2022-11-01 → 2022-11-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
700 µg/L 7%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.00050 mg/L 3.3%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
TTHM
11.66 µg/L 15%
of the EPA limit 80 µg/L
worst single sample: 11.9 µg/L
5/5 SYR4 2012–2019
Bromodichloromethane
3.97 µg/L
No EPA limit set
worst single sample: 4 µg/L
4/4 SYR4 2012–2019
Bromoform
1.485 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
4/4 SYR4 2012–2019
Chloroform
3.37 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
4/4 SYR4 2012–2019
Dibromochloromethane
4.16 µg/L
No EPA limit set
worst single sample: 4.4 µg/L
4/4 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
6.563 µg/L 11%
of the EPA limit 60 µg/L
worst single sample: 7.1 µg/L
4/5 SYR4 2012–2019
Barium
88.45 µg/L 4.4%
of the EPA limit 2000 µg/L
worst single sample: 89 µg/L
2/2 SYR4 2014–2019
Dibromoacetic Acid
1.295 µg/L
No EPA limit set
worst single sample: 1.3 µg/L
2/3 SYR4 2017–2019
Dichloroacetic Acid
2.62 µg/L
No EPA limit set
worst single sample: 2.7 µg/L
2/3 SYR4 2017–2019
Selenium
4.9 µg/L 9.8%
of the EPA limit 50 µg/L
worst single sample: 5 µg/L
2/2 SYR4 2014–2019
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
1/2 SYR4 2014–2019
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
1/2 SYR4 2014–2019
Combined Radium (-226 And -228)
0.9000 pCi/L 18%
of the EPA limit 5 pCi/L
1/1 SYR4 2019
Gross Alpha, Excl. Radon And U
0.7000 pCi/L 4.7%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
Monobromoacetic Acid
2 µg/L
No EPA limit set
1/3 SYR4 2017–2019
Monochloroacetic Acid
1.1 µg/L
No EPA limit set
1/3 SYR4 2017–2019
Nitrate-Nitrite
300 µg/L 3%
of the EPA limit 10000 µg/L
1/1 SYR4 2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HARPER, ROB
Phone
970-275-1758
Email
billing@toadpropertymanagement.com

Frequently asked questions about Buckhorn Ranch Ws

Is Buckhorn Ranch Ws tap water safe to drink?

EPA monitoring detected 19 contaminants in Buckhorn Ranch Ws's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Buckhorn Ranch Ws's water?

EPA monitoring detected Nitrate, Lead, TTHM, Bromodichloromethane, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Buckhorn Ranch Ws serve?

Buckhorn Ranch Ws reports serving 205 people in Colorado, per its EPA record.

Has Buckhorn Ranch Ws had any water quality violations?

The EPA has 74 violations on file for Buckhorn Ranch Ws, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.