Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2013-08-01 → 2013-08-31 |
| MCL | Health-based | Resolved | 2013-08-01 → 2013-08-31 |
| MCL | Health-based | Resolved | 2013-08-01 → 2013-08-31 |
| MCL | Health-based | Resolved | 2013-08-01 → 2013-08-31 |
| MON | Monitoring | Resolved | 2025-04-01 → 2025-04-30 |
| MON | Monitoring | Resolved | 2025-04-01 → 2025-04-30 |
| MON | Monitoring | Resolved | 2025-04-01 → 2025-04-30 |
| MR | Monitoring | Resolved | 2025-04-01 → 2025-06-30 |
| MR | Monitoring | Resolved | 2025-04-01 → 2025-06-30 |
| MR | Monitoring | Resolved | 2025-04-01 → 2025-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 990 µg/L 9.9% of the EPA limit 10000 µg/L | 18/18 | SYR4 | 2012–2019 |
| TTHM | 124 µg/L 155% of the EPA limit, in the worst sample — 80 µg/L | 17/25 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 36.9 µg/L 62% of the EPA limit 60 µg/L | 15/23 | SYR4 | 2012–2019 |
| Lead | 0.0040 mg/L 27% of the EPA limit 0.0150 mg/L | 13/13 | LCR | 2025 |
| Bromoform | 14.7 µg/L No EPA limit set | 11/20 | SYR4 | 2015–2019 |
| Chloroform | 54.8 µg/L No EPA limit set | 11/20 | SYR4 | 2015–2019 |
| Dibromochloromethane | 25.7 µg/L No EPA limit set | 11/20 | SYR4 | 2015–2019 |
| Bromodichloromethane | 21.8 µg/L No EPA limit set | 10/20 | SYR4 | 2015–2019 |
| Dibromoacetic Acid | 11.2 µg/L No EPA limit set | 10/18 | SYR4 | 2015–2019 |
| Dichloroacetic Acid | 7.7 µg/L No EPA limit set | 9/18 | SYR4 | 2015–2019 |
| Monobromoacetic Acid | 4.6 µg/L No EPA limit set | 6/18 | SYR4 | 2015–2019 |
| Trichloroacetic Acid | 28.1 µg/L No EPA limit set | 6/18 | SYR4 | 2015–2019 |
| Combined Uranium | 21 µg/L 70% of the EPA limit 30 µg/L | 4/4 | SYR4 | 2013–2017 |
| Gross Alpha, Excl. Radon And U | 8.27 pCi/L 55% of the EPA limit 15 pCi/L | 4/4 | SYR4 | 2013–2017 |
| Barium | 33 µg/L 1.7% of the EPA limit 2000 µg/L | 3/3 | SYR4 | 2013–2017 |
| Fluoride | 680 µg/L 17% of the EPA limit 4000 µg/L | 3/3 | SYR4 | 2013–2017 |
| Monochloroacetic Acid | 10 µg/L No EPA limit set | 3/18 | SYR4 | 2015–2019 |
| Selenium | 11 µg/L 22% of the EPA limit 50 µg/L | 3/3 | SYR4 | 2013–2017 |
| Arsenic | 1.9 µg/L 19% of the EPA limit 10 µg/L | 2/3 | SYR4 | 2013–2017 |
| Di(2-ethylhexyl) Phthalate | 1.5 µg/L 25% of the EPA limit 6 µg/L | 2/10 | SYR4 | 2012–2019 |
| Chromium | 13 µg/L 13% of the EPA limit 100 µg/L | 1/3 | SYR4 | 2013–2017 |
| Combined Radium (-226 And -228) | 0.3000 pCi/L 6% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2014 |
| Hexachlorocyclopentadiene | 0.0760 µg/L 0.2% of the EPA limit 50 µg/L | 1/3 | SYR4 | 2015–2017 |
| Nitrate-Nitrite | 710 µg/L 7.1% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2014 |
53 contaminants tested, none detected
Utility contact
Frequently asked questions about Mineota Estates Hoa
Is Mineota Estates Hoa tap water safe to drink?
EPA monitoring detected 24 contaminants in Mineota Estates Hoa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Mineota Estates Hoa's water?
EPA monitoring detected Nitrate, TTHM, Total Haloacetic Acids (HAA5), Lead, Bromoform, and others. The full list with the level and data source for each is above.
How many people does Mineota Estates Hoa serve?
Mineota Estates Hoa reports serving 105 people in Colorado, per its EPA record.
Has Mineota Estates Hoa had any water quality violations?
The EPA has 116 violations on file for Mineota Estates Hoa, of which 4 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.