← Colorado

Tap water quality report

Wigwam Mutual Wc

EPA monitoring tested this supplier for 78 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
19
detected
1,300
people served
0
health-based violations
Water source
Ground water under surface influence
Ownership
Private
Counties served
El Paso

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
166
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 2026-01-01 → 2026-03-31
MR Monitoring Archived 2026-01-01 → 2026-03-31
MR Monitoring Archived 2026-01-01 → 2026-03-31
MR Monitoring Archived 2026-01-01 → 2026-03-31
MR Monitoring Resolved 2024-04-01 → 2024-04-30
MR Monitoring Resolved 2024-04-01 → 2024-04-30
MR Monitoring Resolved 2024-04-01 → 2024-04-30
MR Monitoring Resolved 2024-04-01 → 2024-04-30
MR Monitoring Resolved 2024-04-01 → 2024-04-30
MR Monitoring Resolved 2024-04-01 → 2024-04-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
76.07 µg/L 95%
of the EPA limit 80 µg/L
worst single sample: 77.9 µg/L
32/32 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
26.225 µg/L 44%
of the EPA limit 60 µg/L
worst single sample: 27.1 µg/L
32/32 SYR4 2012–2019
Bromodichloromethane
6.81 µg/L
No EPA limit set
worst single sample: 6.9 µg/L
19/21 SYR4 2012–2019
Bromoform
44.4 µg/L
No EPA limit set
worst single sample: 48 µg/L
19/21 SYR4 2012–2019
Dibromochloromethane
26.1 µg/L
No EPA limit set
worst single sample: 27 µg/L
19/21 SYR4 2012–2019
Dibromoacetic Acid
16.15 µg/L
No EPA limit set
worst single sample: 17 µg/L
18/18 SYR4 2015–2019
Nitrate
3100 µg/L 31%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0055 mg/L 37%
of the EPA limit 0.0150 mg/L
15/15 LCR 2025
Chloroform
1.135 µg/L
No EPA limit set
worst single sample: 1.2 µg/L
14/21 SYR4 2012–2019
Dichloroacetic Acid
2.055 µg/L
No EPA limit set
worst single sample: 2.1 µg/L
10/18 SYR4 2015–2019
Monobromoacetic Acid
2.06 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
9/18 SYR4 2015–2019
Fluoride
2265 µg/L 57%
of the EPA limit 4000 µg/L
worst single sample: 2300 µg/L
8/8 SYR4 2012–2019
Barium
16 µg/L 0.8%
of the EPA limit 2000 µg/L
1/1 SYR4 2012
Combined Radium (-226 And -228)
0.9400 pCi/L 19%
of the EPA limit 5 pCi/L
1/1 SYR4 2014
Combined Uranium
9.4 µg/L 31%
of the EPA limit 30 µg/L
1/1 SYR4 2014
Gross Alpha, Excl. Radon And U
2.4 pCi/L 16%
of the EPA limit 15 pCi/L
1/1 SYR4 2014
Nitrate-Nitrite
2700 µg/L 27%
of the EPA limit 10000 µg/L
1/1 SYR4 2012
Selenium
38 µg/L 76%
of the EPA limit 50 µg/L
1/1 SYR4 2012
Xylenes, Total
1.1 µg/L 0%
of the EPA limit 10000 µg/L
1/20 SYR4 2012–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DEVORE, CHARLES K
Phone
719-491-1666
Email
WATERSPECIALTIES@HOTMAIL.COM

Frequently asked questions about Wigwam Mutual Wc

Is Wigwam Mutual Wc tap water safe to drink?

EPA monitoring detected 19 contaminants in Wigwam Mutual Wc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Wigwam Mutual Wc's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Bromoform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Wigwam Mutual Wc serve?

Wigwam Mutual Wc reports serving 1,300 people in Colorado, per its EPA record.

Has Wigwam Mutual Wc had any water quality violations?

The EPA has 166 violations on file for Wigwam Mutual Wc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.