← Colorado

Tap water quality report

Mid Colorado Investment

EPA monitoring tested this supplier for 67 contaminants and detected 6. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

67
contaminants tested
6
detected
0
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
El Paso

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
198
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2020-07-01
Other Monitoring Resolved 2020-07-01
Other Monitoring Resolved 2020-07-01
MR Monitoring Resolved 2020-01-01 → 2020-12-31
MR Monitoring Resolved 2020-01-01 → 2020-12-31
MR Monitoring Resolved 2020-01-01 → 2020-12-31
MR Monitoring Resolved 2019-01-01 → 2019-12-31
MR Monitoring Resolved 2019-01-01 → 2019-12-31
MR Monitoring Resolved 2019-01-01 → 2019-12-31
MR Monitoring Resolved 2017-01-01 → 2019-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
27 µg/L 0.3%
of the EPA limit 10000 µg/L
8/14 SYR4 2012–2018
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
5/5 LCR 2001
Fluoride
1100 µg/L 28%
of the EPA limit 4000 µg/L
3/3 SYR4 2012–2018
Combined Radium (-226 And -228)
1.7 pCi/L 34%
of the EPA limit 5 pCi/L
2/2 SYR4 2012–2015
Barium
5.8 µg/L 0.3%
of the EPA limit 2000 µg/L
1/1 SYR4 2014
Nitrate-Nitrite
27 µg/L 0.3%
of the EPA limit 10000 µg/L
1/1 SYR4 2012
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HARRIS, REBECCA
Phone
719-447-1777
Email
rebecca.h@wsdistricts.co

Frequently asked questions about Mid Colorado Investment

Is Mid Colorado Investment tap water safe to drink?

EPA monitoring detected 6 contaminants in Mid Colorado Investment's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Mid Colorado Investment's water?

EPA monitoring detected Nitrate, Lead, Fluoride, Combined Radium (-226 And -228), Barium, and others. The full list with the level and data source for each is above.

How many people does Mid Colorado Investment serve?

Mid Colorado Investment reports serving 0 people in Colorado, per its EPA record.

Has Mid Colorado Investment had any water quality violations?

The EPA has 198 violations on file for Mid Colorado Investment, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.