Tap water quality report

Pine Brook Hills Wd

EPA monitoring tested this supplier for 76 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

76
contaminants tested
18
detected
1,100
people served
15
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Boulder

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

15
health-based violations
15
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-04-01 → 2008-06-30
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-03-31
MCL Health-based Resolved 2007-10-01 → 2007-12-31
MCL Health-based Resolved 2007-10-01 → 2007-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
126.8 µg/L 159%
of the EPA limit, in the worst sample — 80 µg/L
36/36 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
53.4 µg/L 89%
of the EPA limit 60 µg/L
34/34 SYR4 2012–2019
Bromodichloromethane
23 µg/L
No EPA limit set
19/19 SYR4 2012–2019
Chloroform
59 µg/L
No EPA limit set
19/19 SYR4 2012–2019
Dibromochloromethane
11 µg/L
No EPA limit set
19/19 SYR4 2012–2019
Dichloroacetic Acid
19 µg/L
No EPA limit set
16/16 SYR4 2015–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
16/16 LCR 2025
Trichloroacetic Acid
14 µg/L
No EPA limit set
16/16 SYR4 2015–2019
Nitrate
900 µg/L 9%
of the EPA limit 10000 µg/L
14/16 SYR4 2012–2019
Dibromoacetic Acid
1.9 µg/L
No EPA limit set
12/16 SYR4 2015–2019
Bromoform
0.9000 µg/L
No EPA limit set
10/19 SYR4 2012–2019
Barium
100 µg/L 5%
of the EPA limit 2000 µg/L
8/8 SYR4 2012–2019
Fluoride
1140 µg/L 28%
of the EPA limit 4000 µg/L
7/8 SYR4 2012–2019
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
6/8 SYR4 2012–2019
Selenium
2 µg/L 4%
of the EPA limit 50 µg/L
3/8 SYR4 2012–2019
Arsenic
1 µg/L 10%
of the EPA limit 10 µg/L
2/8 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
0.5000 pCi/L 3.3%
of the EPA limit 15 pCi/L
1/1 SYR4 2017
Monochloroacetic Acid
2.5 µg/L
No EPA limit set
1/16 SYR4 2015–2019
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)Combined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CHURNSIDE, ANDREW
Phone
303-443-5394
Email
contact@pinebrookwater.com

Frequently asked questions about Pine Brook Hills Wd

Is Pine Brook Hills Wd tap water safe to drink?

EPA monitoring detected 18 contaminants in Pine Brook Hills Wd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pine Brook Hills Wd's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Pine Brook Hills Wd serve?

Pine Brook Hills Wd reports serving 1,100 people in Colorado, per its EPA record.

Has Pine Brook Hills Wd had any water quality violations?

The EPA has 15 violations on file for Pine Brook Hills Wd, of which 15 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.