← California

Tap water quality report

Meiners Oaks Cwd

EPA monitoring tested this supplier for 110 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
21
detected
4,200
people served
6
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Ventura

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

6
health-based violations
23
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2009-08-01 → 2009-08-31
TT Health-based Resolved 2009-08-01 → 2009-08-31
MCL Health-based Resolved 2005-10-01 → 2005-10-31
MCL Health-based Resolved 2005-10-01 → 2005-10-31
TT Health-based Resolved 1993-06-01 → 1993-07-30
TT Health-based Resolved 1993-06-01 → 1993-07-30
MON Monitoring Resolved 2023-04-01 → 2023-04-30
MON Monitoring Resolved 2023-04-01 → 2023-04-30
MON Monitoring Resolved 2023-04-01 → 2023-04-30
MR Monitoring Resolved 2007-10-01 → 2007-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
17198.6 µg/L 172%
of the EPA limit, in the worst sample — 10000 µg/L
168/170 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
33/33 LCR 2023
Dibromochloromethane
7 µg/L
No EPA limit set
13/15 SYR4 2012–2019
TTHM
84 µg/L 105%
of the EPA limit, in the worst sample — 80 µg/L
13/15 SYR4 2012–2019
Lithium
74.1 µg/L
No EPA limit set
12/12 UCMR-5 2024
Bromodichloromethane
21 µg/L
No EPA limit set
11/15 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
59 µg/L 98%
of the EPA limit 60 µg/L
11/15 SYR4 2012–2019
Fluoride
600 µg/L 15%
of the EPA limit 4000 µg/L
9/9 SYR4 2014–2018
Bromoform
3 µg/L
No EPA limit set
8/15 SYR4 2012–2019
Dichloroacetic Acid
30 µg/L
No EPA limit set
8/15 SYR4 2012–2019
Selenium
7 µg/L 14%
of the EPA limit 50 µg/L
8/10 SYR4 2014–2018
Chloroform
56 µg/L
No EPA limit set
7/15 SYR4 2012–2019
Nitrate-Nitrite
700000 µg/L 7000%
of the EPA limit, in the worst sample — 10000 µg/L
7/7 SYR4 2014–2018
Dibromoacetic Acid
3 µg/L
No EPA limit set
6/15 SYR4 2012–2019
Trichloroacetic Acid
29 µg/L
No EPA limit set
6/15 SYR4 2012–2019
Barium
40.4 µg/L 2%
of the EPA limit 2000 µg/L
5/10 SYR4 2014–2018
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
5/10 SYR4 2014–2018
Combined Uranium
2.2499 µg/L 7.5%
of the EPA limit 30 µg/L
4/4 SYR4 2017
Monochloroacetic Acid
9 µg/L
No EPA limit set
4/15 SYR4 2012–2019
Lead
0.6000 µg/L 4%
of the EPA limit 15 µg/L
1/10 SYR4 2014–2018
Monobromoacetic Acid
2 µg/L
No EPA limit set
1/15 SYR4 2012–2019
89 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
WARD, SUMMER
Phone
805-646-2114
Email
summer@meinersoakswater.com

Frequently asked questions about Meiners Oaks Cwd

Is Meiners Oaks Cwd tap water safe to drink?

EPA monitoring detected 21 contaminants in Meiners Oaks Cwd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Meiners Oaks Cwd's water?

EPA monitoring detected Nitrate, Lead, Dibromochloromethane, TTHM, Lithium, and others. The full list with the level and data source for each is above.

How many people does Meiners Oaks Cwd serve?

Meiners Oaks Cwd reports serving 4,200 people in California, per its EPA record.

Has Meiners Oaks Cwd had any water quality violations?

The EPA has 23 violations on file for Meiners Oaks Cwd, of which 6 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.