← California

Tap water quality report

Lsid-Strathmore

EPA monitoring tested this supplier for 12 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

12
contaminants tested
11
detected
500
people served
1
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Tulare

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
15
violations on file
3
still open
ViolationTypeStatusPeriod
TT Health-based Addressed 2024-10-17
RPT Monitoring Addressed 2024-10-17
MR Monitoring Addressed 2024-10-01
MON Monitoring Resolved 2017-02-01 → 2017-02-28
MON Monitoring Resolved 2017-02-01 → 2017-02-28
MR Monitoring Resolved 2004-10-01 → 2004-12-31
MR Monitoring Resolved 2004-10-01 → 2004-12-31
MR Monitoring Resolved 2003-06-01 → 2003-06-30
MR Monitoring Resolved 2003-06-01 → 2003-06-30
MR Monitoring Resolved 2003-05-01 → 2003-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
17/17 LCR 2025
Bromodichloromethane
31.5 µg/L
No EPA limit set
worst single sample: 33 µg/L
16/16 SYR4 2015–2019
Chloroform
96.75 µg/L
No EPA limit set
worst single sample: 120 µg/L
16/16 SYR4 2015–2019
Dichloroacetic Acid
44.5 µg/L
No EPA limit set
worst single sample: 88 µg/L
16/16 SYR4 2015–2019
TTHM
122.5 µg/L 153%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 130 µg/L
16/16 SYR4 2015–2019
Total Haloacetic Acids (HAA5)
122.5 µg/L 204%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 190 µg/L
16/16 SYR4 2015–2019
Trichloroacetic Acid
76.75 µg/L
No EPA limit set
worst single sample: 100 µg/L
16/16 SYR4 2015–2019
Dibromochloromethane
10.09 µg/L
No EPA limit set
worst single sample: 11 µg/L
14/16 SYR4 2015–2019
Dibromoacetic Acid
2.375 µg/L
No EPA limit set
worst single sample: 2.7 µg/L
6/16 SYR4 2015–2019
Monochloroacetic Acid
4.7 µg/L
No EPA limit set
worst single sample: 5 µg/L
4/16 SYR4 2015–2019
Bromoform
1.2 µg/L
No EPA limit set
1/16 SYR4 2015–2019
1 contaminants tested, none detected
Monobromoacetic Acid

Utility contact

Contact
WALLACE, CRAIG
Phone
559-562-2581
Email
cwallace@lsid.org

Frequently asked questions about Lsid-Strathmore

Is Lsid-Strathmore tap water safe to drink?

EPA monitoring detected 11 contaminants in Lsid-Strathmore's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lsid-Strathmore's water?

EPA monitoring detected Lead, Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Lsid-Strathmore serve?

Lsid-Strathmore reports serving 500 people in California, per its EPA record.

Has Lsid-Strathmore had any water quality violations?

The EPA has 15 violations on file for Lsid-Strathmore, of which 1 is health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.