← California

Tap water quality report

Bodega Water Company

EPA monitoring tested this supplier for 75 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

75
contaminants tested
16
detected
77
people served
23
health-based violations
Water source
Ground water under surface influence
Ownership
Private
Counties served
Sonoma

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

23
health-based violations
58
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2020-10-01 → 2020-12-31
MCL Health-based Resolved 2015-10-01 → 2015-12-31
MCL Health-based Resolved 2015-10-01 → 2015-12-31
MCL Health-based Resolved 2015-07-01 → 2015-09-30
MCL Health-based Resolved 2015-07-01 → 2015-09-30
MCL Health-based Resolved 2015-07-01 → 2015-09-30
MCL Health-based Resolved 2015-07-01 → 2015-09-30
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2013-07-01 → 2013-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
4400 µg/L 110%
of the EPA limit, in the worst sample — 4000 µg/L
57/58 SYR4 2012–2019
Nitrate
9200 µg/L 92%
of the EPA limit 10000 µg/L
42/82 SYR4 2012–2019
Bromodichloromethane
54 µg/L
No EPA limit set
32/35 SYR4 2012–2019
Chloroform
100 µg/L
No EPA limit set
32/35 SYR4 2012–2019
Dibromochloromethane
30 µg/L
No EPA limit set
32/35 SYR4 2012–2019
TTHM
190 µg/L 238%
of the EPA limit, in the worst sample — 80 µg/L
32/34 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
190 µg/L 317%
of the EPA limit, in the worst sample — 60 µg/L
32/32 SYR4 2012–2019
Dichloroacetic Acid
28 µg/L
No EPA limit set
30/32 SYR4 2012–2019
Bromoform
7.2 µg/L
No EPA limit set
29/35 SYR4 2012–2019
Trichloroacetic Acid
29.1 µg/L
No EPA limit set
28/32 SYR4 2012–2019
Lead
0.0018 mg/L 12%
of the EPA limit 0.0150 mg/L
26/26 LCR 2023
Dibromoacetic Acid
6.9 µg/L
No EPA limit set
21/31 SYR4 2012–2019
Monobromoacetic Acid
24 µg/L
No EPA limit set
8/31 SYR4 2012–2019
Monochloroacetic Acid
180 µg/L
No EPA limit set
8/31 SYR4 2012–2019
Barium
100 µg/L 5%
of the EPA limit 2000 µg/L
5/13 SYR4 2013–2019
Asbestos
0.2000 MFL 2.9%
of the EPA limit 7 MFL
1/4 SYR4 2014–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
JONES, THERESA
Phone
707-340-5244
Email
bodegawatercompany@gmail.com

Frequently asked questions about Bodega Water Company

Is Bodega Water Company tap water safe to drink?

EPA monitoring detected 16 contaminants in Bodega Water Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Bodega Water Company's water?

EPA monitoring detected Fluoride, Nitrate, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Bodega Water Company serve?

Bodega Water Company reports serving 77 people in California, per its EPA record.

Has Bodega Water Company had any water quality violations?

The EPA has 58 violations on file for Bodega Water Company, of which 23 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.