← California

Tap water quality report

Rio Lindo Adventist Academy

EPA monitoring tested this supplier for 59 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

59
contaminants tested
14
detected
178
people served
2
health-based violations
Water source
Ground water under surface influence
Ownership
Private
Counties served
Sonoma

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
21
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2001-12-01 → 2001-12-31
MCL Health-based Resolved 2001-12-01 → 2001-12-31
MON Monitoring Resolved 2023-05-01 → 2023-05-31
MON Monitoring Resolved 2023-05-01 → 2023-05-31
MON Monitoring Resolved 2023-04-01 → 2023-04-30
MON Monitoring Resolved 2023-04-01 → 2023-04-30
MR Monitoring Resolved 2009-01-01 → 2009-12-31
MR Monitoring Resolved 2009-01-01 → 2009-12-31
MR Monitoring Resolved 2006-01-01 → 2006-12-31
MR Monitoring Resolved 2006-01-01 → 2006-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
19/19 LCR 2023
Nitrate
316.4 µg/L 3.2%
of the EPA limit 10000 µg/L
8/48 SYR4 2012–2019
Barium
117 µg/L 5.9%
of the EPA limit 2000 µg/L
worst single sample: 120 µg/L
7/8 SYR4 2012–2019
Bromodichloromethane
7.738 µg/L
No EPA limit set
worst single sample: 7.99 µg/L
7/7 SYR4 2012–2019
Chloroform
22.433 µg/L
No EPA limit set
worst single sample: 25.22 µg/L
7/7 SYR4 2012–2019
Dichloroacetic Acid
11.86 µg/L
No EPA limit set
worst single sample: 12.7 µg/L
7/7 SYR4 2012–2019
TTHM
30.062 µg/L 38%
of the EPA limit 80 µg/L
worst single sample: 30.44 µg/L
7/7 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
18.27 µg/L 30%
of the EPA limit 60 µg/L
worst single sample: 18.3 µg/L
7/7 SYR4 2012–2019
Trichloroacetic Acid
4.75 µg/L
No EPA limit set
worst single sample: 4.9 µg/L
7/7 SYR4 2012–2019
Dibromochloromethane
5.21 µg/L
No EPA limit set
worst single sample: 5.36 µg/L
6/7 SYR4 2012–2019
Fluoride
171 µg/L 4.3%
of the EPA limit 4000 µg/L
worst single sample: 180 µg/L
4/8 SYR4 2012–2019
Dibromoacetic Acid
2.37 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
3/7 SYR4 2012–2019
Bromoform
2.498 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
2/7 SYR4 2012–2019
Monochloroacetic Acid
3.885 µg/L
No EPA limit set
worst single sample: 3.9 µg/L
2/7 SYR4 2012–2019
45 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBenzeneBeryllium, TotalChlorobenzeneCopperCadmiumCarbofuranCarbon TetrachlorideChromiumDichloromethaneDalaponDinosebDiquatEndothallEthylbenzeneLassoMercuryMonobromoacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LEPULU, MEKEY
Phone
707-431-5100
Email
principal@riolindo.org

Frequently asked questions about Rio Lindo Adventist Academy

Is Rio Lindo Adventist Academy tap water safe to drink?

EPA monitoring detected 14 contaminants in Rio Lindo Adventist Academy's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Rio Lindo Adventist Academy's water?

EPA monitoring detected Lead, Nitrate, Barium, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Rio Lindo Adventist Academy serve?

Rio Lindo Adventist Academy reports serving 178 people in California, per its EPA record.

Has Rio Lindo Adventist Academy had any water quality violations?

The EPA has 21 violations on file for Rio Lindo Adventist Academy, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.