← California

Tap water quality report

Valley Ford Water Association

EPA monitoring tested this supplier for 71 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

71
contaminants tested
15
detected
88
people served
88
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Sonoma

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

88
health-based violations
110
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-04-01 → 2025-06-30
MCL Health-based Archived 2025-01-01 → 2025-03-31
TT Health-based Unaddressed 2024-10-17
MCL Health-based Archived 2024-10-01 → 2024-12-31
MCL Health-based Archived 2024-07-01 → 2024-09-30
MCL Health-based Archived 2024-04-01 → 2024-06-30
MCL Health-based Archived 2024-01-01 → 2024-03-31
MCL Health-based Archived 2023-10-01 → 2023-12-31
MCL Health-based Archived 2023-10-01 → 2023-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
31640 µg/L 316%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 42940 µg/L
146/152 SYR4 2012–2019
Lead
0.0090 mg/L 60%
of the EPA limit 0.0150 mg/L
10/10 LCR 2024
Fluoride
2900 µg/L 73%
of the EPA limit 4000 µg/L
worst single sample: 3200 µg/L
6/6 SYR4 2014–2017
Barium
876 µg/L 44%
of the EPA limit 2000 µg/L
worst single sample: 990 µg/L
4/5 SYR4 2014–2017
Bromodichloromethane
29.6 µg/L
No EPA limit set
worst single sample: 30 µg/L
3/5 SYR4 2013–2019
Bromoform
26 µg/L
No EPA limit set
3/5 SYR4 2013–2019
Chloroform
10.63 µg/L
No EPA limit set
worst single sample: 11 µg/L
3/5 SYR4 2013–2019
Dibromoacetic Acid
37.4 µg/L
No EPA limit set
worst single sample: 39 µg/L
3/4 SYR4 2013–2019
Dibromochloromethane
54.8 µg/L
No EPA limit set
worst single sample: 55 µg/L
3/5 SYR4 2013–2019
Monobromoacetic Acid
2.292 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
3/4 SYR4 2013–2019
TTHM
119 µg/L 149%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 120 µg/L
3/5 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
67.5 µg/L 113%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 70 µg/L
3/4 SYR4 2013–2019
Dichloroacetic Acid
16.7 µg/L
No EPA limit set
worst single sample: 17 µg/L
2/4 SYR4 2013–2019
Monochloroacetic Acid
6.79 µg/L
No EPA limit set
worst single sample: 6.8 µg/L
2/4 SYR4 2013–2019
Trichloroacetic Acid
4.895 µg/L
No EPA limit set
worst single sample: 5 µg/L
2/4 SYR4 2013–2019
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCopperCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROSENBLUM, JONATHAN
Phone
347-413-3759
Email
jrosenblum00@gmail.com

Frequently asked questions about Valley Ford Water Association

Is Valley Ford Water Association tap water safe to drink?

EPA monitoring detected 15 contaminants in Valley Ford Water Association's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Valley Ford Water Association's water?

EPA monitoring detected Nitrate, Lead, Fluoride, Barium, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Valley Ford Water Association serve?

Valley Ford Water Association reports serving 88 people in California, per its EPA record.

Has Valley Ford Water Association had any water quality violations?

The EPA has 110 violations on file for Valley Ford Water Association, of which 88 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.