Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2012-04-01 → 2012-04-30 |
| MCL | Health-based | Resolved | 2012-04-01 → 2012-04-30 |
| MCL | Health-based | Resolved | 2008-02-01 → 2008-02-29 |
| MCL | Health-based | Resolved | 2008-02-01 → 2008-02-29 |
| MCL | Health-based | Resolved | 1996-07-01 → 1996-07-31 |
| MCL | Health-based | Resolved | 1996-07-01 → 1996-07-31 |
| TT | Health-based | Resolved | 1994-10-01 → 1994-10-31 |
| TT | Health-based | Resolved | 1994-10-01 → 1994-10-31 |
| TT | Health-based | Resolved | 1994-10-01 → 1994-10-31 |
| TT | Health-based | Resolved | 1994-10-01 → 1994-10-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 6400 µg/L 64% of the EPA limit 10000 µg/L | 154/270 | SYR4 | 2012–2019 |
| Dibromochloromethane | 26.4 µg/L No EPA limit set | 55/62 | SYR4 | 2012–2019 |
| TTHM | 74.2 µg/L 93% of the EPA limit 80 µg/L | 55/62 | SYR4 | 2012–2019 |
| Bromodichloromethane | 22.9 µg/L No EPA limit set | 53/62 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 21.5 µg/L 36% of the EPA limit 60 µg/L | 51/56 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 11.3 µg/L No EPA limit set | 49/56 | SYR4 | 2012–2019 |
| Bromoform | 23.4 µg/L No EPA limit set | 48/62 | SYR4 | 2012–2019 |
| Chloroform | 20 µg/L No EPA limit set | 44/62 | SYR4 | 2012–2019 |
| Fluoride | 370 µg/L 9.3% of the EPA limit 4000 µg/L | 36/40 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 36/36 | LCR | 2024 |
| Dichloroacetic Acid | 13.6 µg/L No EPA limit set | 35/56 | SYR4 | 2012–2019 |
| Chromium | 30 µg/L 30% of the EPA limit 100 µg/L | 21/84 | SYR4 | 2012–2019 |
| Combined Uranium | 10.281 µg/L 34% of the EPA limit 30 µg/L | 20/21 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 960000 µg/L 9600% of the EPA limit, in the worst sample — 10000 µg/L | 19/29 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 4.8 µg/L No EPA limit set | 18/56 | SYR4 | 2012–2019 |
| Lithium | 62.2 µg/L No EPA limit set | 16/19 | UCMR-5 | 2025 |
| Arsenic | 3.3 µg/L 33% of the EPA limit 10 µg/L | 11/40 | SYR4 | 2012–2019 |
| Barium | 170 µg/L 8.5% of the EPA limit 2000 µg/L | 5/40 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 3.3 µg/L No EPA limit set | 5/56 | SYR4 | 2012–2019 |
| Selenium | 11 µg/L 22% of the EPA limit 50 µg/L | 5/40 | SYR4 | 2012–2019 |
| Copper | 210 µg/L 16% of the EPA limit 1300 µg/L | 2/42 | SYR4 | 2012–2019 |
| Lead | 22 µg/L 147% of the EPA limit, in the worst sample — 15 µg/L | 2/42 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1.1 µg/L No EPA limit set | 2/56 | SYR4 | 2012–2019 |
| Cadmium | 1.8 µg/L 36% of the EPA limit 5 µg/L | 1/40 | SYR4 | 2012–2019 |
87 contaminants tested, none detected
Utility contact
Frequently asked questions about Santa Ynez River Water Cons. Dist. id#1
Is Santa Ynez River Water Cons. Dist. id#1 tap water safe to drink?
EPA monitoring detected 24 contaminants in Santa Ynez River Water Cons. Dist. id#1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Santa Ynez River Water Cons. Dist. id#1's water?
EPA monitoring detected Nitrate, Dibromochloromethane, TTHM, Bromodichloromethane, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Santa Ynez River Water Cons. Dist. id#1 serve?
Santa Ynez River Water Cons. Dist. id#1 reports serving 7,022 people in California, per its EPA record.
Has Santa Ynez River Water Cons. Dist. id#1 had any water quality violations?
The EPA has 25 violations on file for Santa Ynez River Water Cons. Dist. id#1, of which 25 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.