← California

Tap water quality report

Carpinteria Valley Water District

EPA monitoring tested this supplier for 81 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
22
detected
15,996
people served
8
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Santa Barbara

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
10
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2013-07-01 → 2013-09-30
MCL Health-based Resolved 2013-07-01 → 2013-09-30
MCL Health-based Resolved 2013-04-01 → 2013-06-30
MCL Health-based Resolved 2013-04-01 → 2013-06-30
MCL Health-based Resolved 2008-07-01 → 2008-09-30
MCL Health-based Resolved 2008-07-01 → 2008-09-30
MCL Health-based Resolved 2005-10-01 → 2005-12-31
MCL Health-based Resolved 2005-10-01 → 2005-12-31
MR Monitoring Resolved 1996-05-01 → 1996-05-31
MR Monitoring Resolved 1996-05-01 → 1996-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
26.9 µg/L
No EPA limit set
133/133 SYR4 2012–2019
Dibromochloromethane
35.3 µg/L
No EPA limit set
133/133 SYR4 2012–2019
TTHM
120 µg/L 150%
of the EPA limit, in the worst sample — 80 µg/L
133/133 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
41 µg/L 68%
of the EPA limit 60 µg/L
126/131 SYR4 2012–2019
Bromoform
18.8 µg/L
No EPA limit set
124/133 SYR4 2012–2019
Chloroform
93.8 µg/L
No EPA limit set
119/133 SYR4 2012–2019
Trichloroacetic Acid
19 µg/L
No EPA limit set
102/131 SYR4 2012–2019
Dichloroacetic Acid
21 µg/L
No EPA limit set
98/131 SYR4 2012–2019
Dibromoacetic Acid
12 µg/L
No EPA limit set
86/131 SYR4 2012–2019
Nitrate
9311.2 µg/L 93%
of the EPA limit 10000 µg/L
68/70 SYR4 2012–2019
Monobromoacetic Acid
5 µg/L
No EPA limit set
42/131 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
38/38 LCR 2025
Fluoride
300 µg/L 7.5%
of the EPA limit 4000 µg/L
18/18 SYR4 2012–2019
Nitrate-Nitrite
3300 µg/L 33%
of the EPA limit 10000 µg/L
12/13 SYR4 2016–2019
Lithium
37.3 µg/L
No EPA limit set
9/9 UCMR-5 2024
Monochloroacetic Acid
4 µg/L
No EPA limit set
7/131 SYR4 2012–2019
Barium
90.8 µg/L 4.5%
of the EPA limit 2000 µg/L
5/15 SYR4 2012–2019
Lead
0.7000 µg/L 4.7%
of the EPA limit 15 µg/L
2/15 SYR4 2012–2019
Selenium
3 µg/L 6%
of the EPA limit 50 µg/L
2/15 SYR4 2012–2019
Copper
20 µg/L 1.5%
of the EPA limit 1300 µg/L
1/18 SYR4 2012–2019
Chromium
2 µg/L 2%
of the EPA limit 100 µg/L
1/15 SYR4 2012–2019
Combined Uranium
3.3078 µg/L 11%
of the EPA limit 30 µg/L
1/1 SYR4 2018
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideDichloromethaneEthylbenzeneHfpo-DaMercuryNetfosaaNfdhaNmefosaaNitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
DYER, KELLEY
Phone
805-564-5571
Email
kdyer@santabarbaraca.gov

Frequently asked questions about Carpinteria Valley Water District

Is Carpinteria Valley Water District tap water safe to drink?

EPA monitoring detected 22 contaminants in Carpinteria Valley Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Carpinteria Valley Water District's water?

EPA monitoring detected Bromodichloromethane, Dibromochloromethane, TTHM, Total Haloacetic Acids (HAA5), Bromoform, and others. The full list with the level and data source for each is above.

How many people does Carpinteria Valley Water District serve?

Carpinteria Valley Water District reports serving 15,996 people in California, per its EPA record.

Has Carpinteria Valley Water District had any water quality violations?

The EPA has 10 violations on file for Carpinteria Valley Water District, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.