← California

Tap water quality report

Santa Fe I.D.

EPA monitoring tested this supplier for 114 contaminants and detected 26. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

114
contaminants tested
26
detected
21,578
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
San Diego

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
1
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Archived 1988-12-01 → 1988-12-31

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
Pfhxa 0.0045 µg/L 2/4 2024
Pfpea 0.0043 µg/L 1/4 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
35 µg/L
No EPA limit set
155/155 SYR4 2012–2019
Chloroform
42 µg/L
No EPA limit set
155/155 SYR4 2012–2019
Dibromochloromethane
29 µg/L
No EPA limit set
155/155 SYR4 2012–2019
TTHM
96 µg/L 120%
of the EPA limit, in the worst sample — 80 µg/L
154/154 SYR4 2012–2019
Bromoform
13 µg/L
No EPA limit set
153/155 SYR4 2012–2019
Dichloroacetic Acid
14 µg/L
No EPA limit set
145/147 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
28 µg/L 47%
of the EPA limit 60 µg/L
143/147 SYR4 2012–2019
Dibromoacetic Acid
7.8 µg/L
No EPA limit set
142/147 SYR4 2012–2019
Trichloroacetic Acid
12 µg/L
No EPA limit set
142/147 SYR4 2012–2019
Fluoride
380 µg/L 9.5%
of the EPA limit 4000 µg/L
86/88 SYR4 2012–2019
Arsenic
4.4 µg/L 44%
of the EPA limit 10 µg/L
45/88 SYR4 2012–2019
Lead
0.0017 mg/L 11%
of the EPA limit 0.0150 mg/L
35/35 LCR 2025
Nitrate
860 µg/L 8.6%
of the EPA limit 10000 µg/L
18/178 SYR4 2012–2019
Monobromoacetic Acid
1.2 µg/L
No EPA limit set
11/147 SYR4 2012–2019
Nitrate-Nitrite
810000 µg/L 8100%
of the EPA limit, in the worst sample — 10000 µg/L
8/88 SYR4 2012–2019
Barium
120 µg/L 6%
of the EPA limit 2000 µg/L
4/88 SYR4 2012–2019
Copper
160 µg/L 12%
of the EPA limit 1300 µg/L
4/88 SYR4 2012–2019
Lithium
39.8 µg/L
No EPA limit set
4/4 UCMR-5 2024
Gross Beta Particle Activity
5.9 pCi/L
No EPA limit set
3/3 SYR4 2014
Combined Uranium
5.066 µg/L 17%
of the EPA limit 30 µg/L
2/3 SYR4 2014
Monochloroacetic Acid
2.2 µg/L
No EPA limit set
2/147 SYR4 2012–2019
Chlorite
460 µg/L 46%
of the EPA limit 1000 µg/L
1/1 SYR4 2019
Lead
39 µg/L 260%
of the EPA limit, in the worst sample — 15 µg/L
1/85 SYR4 2012–2019
Selenium
6.1 µg/L 12%
of the EPA limit 50 µg/L
1/88 SYR4 2012–2019
88 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromateChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
LAU, AL
Phone
858-756-2424
Email
Alau@SFIDWater.org

Frequently asked questions about Santa Fe I.D.

Is Santa Fe I.D. tap water safe to drink?

EPA monitoring detected 26 contaminants in Santa Fe I.D.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Santa Fe I.D.'s water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Santa Fe I.D. serve?

Santa Fe I.D. reports serving 21,578 people in California, per its EPA record.

Has Santa Fe I.D. had any water quality violations?

The EPA has 1 violation on file for Santa Fe I.D., of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.