← California

Tap water quality report

Deer Lodge Water

EPA monitoring tested this supplier for 52 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

52
contaminants tested
15
detected
845
people served
0
health-based violations
Water source
SWP
Ownership
Private
Counties served
San Bernardino

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
4
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 1993-07-01
MR Monitoring Archived 1981-10-01 → 1982-09-30
MR Monitoring Archived 1980-10-30 → 1981-10-29
Other Monitoring Archived 1980-02-28 → 1980-03-27

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Combined Uranium
42.465 µg/L 142%
of the EPA limit, at the 95th percentile of samples — 30 µg/L
worst single sample: 44.7 µg/L
31/119 SYR4 2012–2019
Dibromochloromethane
15.39 µg/L
No EPA limit set
worst single sample: 17.1 µg/L
22/28 SYR4 2016–2019
Nitrate
541.28 µg/L 5.4%
of the EPA limit 10000 µg/L
worst single sample: 542.4 µg/L
22/34 SYR4 2012–2019
TTHM
45.375 µg/L 57%
of the EPA limit 80 µg/L
worst single sample: 46.8 µg/L
22/28 SYR4 2016–2019
Bromodichloromethane
8.295 µg/L
No EPA limit set
worst single sample: 12 µg/L
20/28 SYR4 2016–2019
Bromoform
19.855 µg/L
No EPA limit set
worst single sample: 22.8 µg/L
20/28 SYR4 2016–2019
Dibromoacetic Acid
6.84 µg/L
No EPA limit set
worst single sample: 8.2 µg/L
18/28 SYR4 2016–2019
Total Haloacetic Acids (HAA5)
8.085 µg/L 13%
of the EPA limit 60 µg/L
worst single sample: 9.7 µg/L
18/28 SYR4 2016–2019
Chloroform
8.54 µg/L
No EPA limit set
worst single sample: 9.1 µg/L
17/28 SYR4 2016–2019
Fluoride
205 µg/L 5.1%
of the EPA limit 4000 µg/L
worst single sample: 220 µg/L
16/17 SYR4 2012–2019
Dichloroacetic Acid
2.2 µg/L
No EPA limit set
11/28 SYR4 2016–2019
Nitrate-Nitrite
525000 µg/L 5250%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 540000 µg/L
11/14 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
5/5 LCR 2025
Copper
56 µg/L 4.3%
of the EPA limit 1300 µg/L
1/17 SYR4 2012–2019
Lead
41 µg/L 273%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
1/17 SYR4 2012–2019
37 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicBariumBenzeneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylene DibromideEthylbenzeneMercuryMonobromoacetic AcidMonochloroacetic AcidNitriteSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GROSS, RYAN
Phone
909-336-7102
Email
rgross@lakearrowheadcsd.com

Frequently asked questions about Deer Lodge Water

Is Deer Lodge Water tap water safe to drink?

EPA monitoring detected 15 contaminants in Deer Lodge Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Deer Lodge Water's water?

EPA monitoring detected Combined Uranium, Dibromochloromethane, Nitrate, TTHM, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Deer Lodge Water serve?

Deer Lodge Water reports serving 845 people in California, per its EPA record.

Has Deer Lodge Water had any water quality violations?

The EPA has 4 violations on file for Deer Lodge Water, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.