← California

Tap water quality report

Scwa - Arden Park Vista

EPA monitoring tested this supplier for 99 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

99
contaminants tested
9
detected
10,101
people served
1
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Sacramento

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
4
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2024-10-17
RPT Monitoring Unaddressed 2024-10-17
MR Monitoring Resolved 2004-11-01 → 2004-11-30
MR Monitoring Resolved 2004-11-01 → 2004-11-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFOS 0.0060 µg/L 4/19 2025
Pfpea 0.0036 µg/L 1/19 2025

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
5424 µg/L 54%
of the EPA limit 10000 µg/L
worst single sample: 5650 µg/L
172/204 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
35/35 LCR 2025
Nitrate-Nitrite
344120 µg/L 3441%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 570000 µg/L
9/13 SYR4 2014–2018
Arsenic
3.36 µg/L 34%
of the EPA limit 10 µg/L
worst single sample: 3.5 µg/L
5/21 SYR4 2012–2018
Fluoride
1284.5 µg/L 32%
of the EPA limit 4000 µg/L
worst single sample: 1400 µg/L
4/81 SYR4 2012–2019
Combined Uranium
2.6373 µg/L 8.8%
of the EPA limit 30 µg/L
worst single sample: 2.682 µg/L
2/10 SYR4 2015–2016
Barium
100 µg/L 5%
of the EPA limit 2000 µg/L
1/21 SYR4 2012–2018
90 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HUTCHESON, SCOTT
Phone
916-875-2216
Email
HUTCHESONS@SACCOUNTY.NET

Frequently asked questions about Scwa - Arden Park Vista

Is Scwa - Arden Park Vista tap water safe to drink?

EPA monitoring detected 9 contaminants in Scwa - Arden Park Vista's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Scwa - Arden Park Vista's water?

EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite, Arsenic, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Scwa - Arden Park Vista serve?

Scwa - Arden Park Vista reports serving 10,101 people in California, per its EPA record.

Has Scwa - Arden Park Vista had any water quality violations?

The EPA has 4 violations on file for Scwa - Arden Park Vista, of which 1 is health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.