Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2014-05-01 → 2014-05-31 |
| MCL | Health-based | Resolved | 2014-05-01 → 2014-05-31 |
| MCL | Health-based | Resolved | 2011-04-01 → 2011-06-30 |
| MCL | Health-based | Resolved | 2011-04-01 → 2011-06-30 |
| MCL | Health-based | Resolved | 2008-07-01 → 2008-07-31 |
| MCL | Health-based | Resolved | 2008-07-01 → 2008-07-31 |
| MCL | Health-based | Resolved | 1985-01-01 → 1985-01-31 |
| MCL | Health-based | Resolved | 1985-01-01 → 1985-01-31 |
| MCL | Health-based | Resolved | 1985-01-01 → 1985-01-31 |
| MCL | Health-based | Resolved | 1985-01-01 → 1985-01-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 19436 µg/L 194% of the EPA limit, in the worst sample — 10000 µg/L | 554/564 | SYR4 | 2012–2019 |
| Fluoride | 3800 µg/L 95% of the EPA limit 4000 µg/L | 85/85 | SYR4 | 2012–2018 |
| TTHM | 47 µg/L 59% of the EPA limit 80 µg/L | 45/51 | SYR4 | 2014–2019 |
| Bromoform | 12 µg/L No EPA limit set | 43/59 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 36/36 | LCR | 2025 |
| Dibromochloromethane | 21 µg/L No EPA limit set | 17/59 | SYR4 | 2012–2019 |
| Bromodichloromethane | 13 µg/L No EPA limit set | 14/59 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 4.4 µg/L No EPA limit set | 14/51 | SYR4 | 2014–2019 |
| Combined Uranium | 6.0792 µg/L 20% of the EPA limit 30 µg/L | 12/12 | SYR4 | 2012–2016 |
| Chloroform | 5.1 µg/L No EPA limit set | 11/59 | SYR4 | 2012–2019 |
| Chromium | 5.7 µg/L 5.7% of the EPA limit 100 µg/L | 10/20 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 5.8 µg/L No EPA limit set | 10/51 | SYR4 | 2014–2019 |
| Total Haloacetic Acids (HAA5) | 10 µg/L 17% of the EPA limit 60 µg/L | 10/51 | SYR4 | 2014–2019 |
| Barium | 110 µg/L 5.5% of the EPA limit 2000 µg/L | 9/20 | SYR4 | 2012–2019 |
| Arsenic | 3.9 µg/L 39% of the EPA limit 10 µg/L | 7/23 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 1000000 µg/L 10000% of the EPA limit, in the worst sample — 10000 µg/L | 5/5 | SYR4 | 2014–2017 |
| Lithium | 16 µg/L No EPA limit set | 4/6 | UCMR-5 | 2025 |
| Monochloroacetic Acid | 6 µg/L No EPA limit set | 3/51 | SYR4 | 2014–2019 |
| Selenium | 12 µg/L 24% of the EPA limit 50 µg/L | 3/20 | SYR4 | 2012–2019 |
| Copper | 150 µg/L 12% of the EPA limit 1300 µg/L | 2/33 | SYR4 | 2012–2018 |
| Dichloroacetic Acid | 2.2 µg/L No EPA limit set | 2/51 | SYR4 | 2014–2019 |
90 contaminants tested, none detected
Utility contact
Frequently asked questions about Hemet, City of
Is Hemet, City of tap water safe to drink?
EPA monitoring detected 21 contaminants in Hemet, City of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Hemet, City of's water?
EPA monitoring detected Nitrate, Fluoride, TTHM, Bromoform, Lead, and others. The full list with the level and data source for each is above.
How many people does Hemet, City of serve?
Hemet, City of reports serving 33,828 people in California, per its EPA record.
Has Hemet, City of had any water quality violations?
The EPA has 49 violations on file for Hemet, City of, of which 33 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.