Compliance record
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 7537.1 µg/L 75% of the EPA limit 10000 µg/L | 274/318 | SYR4 | 2012–2019 |
| TTHM | 82 µg/L 102% of the EPA limit, in the worst sample — 80 µg/L | 124/125 | SYR4 | 2012–2019 |
| Bromoform | 8.1 µg/L No EPA limit set | 117/125 | SYR4 | 2012–2019 |
| Dibromochloromethane | 29 µg/L No EPA limit set | 116/125 | SYR4 | 2012–2019 |
| Chloroform | 21 µg/L No EPA limit set | 114/125 | SYR4 | 2012–2019 |
| Bromodichloromethane | 23 µg/L No EPA limit set | 107/125 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 37 µg/L 62% of the EPA limit 60 µg/L | 102/124 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 7 µg/L No EPA limit set | 97/124 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 14 µg/L No EPA limit set | 97/124 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 8.9 µg/L No EPA limit set | 75/124 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 810000 µg/L 8100% of the EPA limit, in the worst sample — 10000 µg/L | 53/59 | SYR4 | 2012–2019 |
| Fluoride | 770 µg/L 19% of the EPA limit 4000 µg/L | 32/32 | SYR4 | 2012–2019 |
| Lead | 0.0025 mg/L 17% of the EPA limit 0.0150 mg/L | 32/32 | LCR | 2025 |
| Combined Uranium | 10.2959 µg/L 34% of the EPA limit 30 µg/L | 29/42 | SYR4 | 2012–2017 |
| Monobromoacetic Acid | 14 µg/L No EPA limit set | 29/124 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 9.1 µg/L No EPA limit set | 26/124 | SYR4 | 2012–2019 |
| Gross Beta Particle Activity | 2.25 pCi/L No EPA limit set | 6/6 | SYR4 | 2012–2014 |
| Lithium | 35.257 µg/L No EPA limit set | 6/10 | UCMR-5 | 2025 |
| Combined Radium (-226 And -228) | 0.5190 pCi/L 10% of the EPA limit 5 pCi/L | 5/5 | SYR4 | 2012–2013 |
| Selenium | 7.7 µg/L 15% of the EPA limit 50 µg/L | 3/33 | SYR4 | 2012–2019 |
85 contaminants tested, none detected
Utility contact
Frequently asked questions about Golden State Wc - Placentia/Yorba Linda
Is Golden State Wc - Placentia/Yorba Linda tap water safe to drink?
EPA monitoring detected 27 contaminants in Golden State Wc - Placentia/Yorba Linda's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Golden State Wc - Placentia/Yorba Linda's water?
EPA monitoring detected Nitrate, TTHM, Bromoform, Dibromochloromethane, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Golden State Wc - Placentia/Yorba Linda serve?
Golden State Wc - Placentia/Yorba Linda reports serving 50,381 people in California, per its EPA record.
Has Golden State Wc - Placentia/Yorba Linda had any water quality violations?
The EPA has no formal drinking-water violations on file for Golden State Wc - Placentia/Yorba Linda.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.