← California

Tap water quality report

Berryessa Pines Water

EPA monitoring tested this supplier for 71 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

71
contaminants tested
12
detected
261
people served
5
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Napa

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
29
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2024-10-17
MCL Health-based Resolved 2006-01-01 → 2006-03-31
MCL Health-based Resolved 2006-01-01 → 2006-03-31
MCL Health-based Resolved 2005-10-01 → 2005-12-31
MCL Health-based Resolved 2005-10-01 → 2005-12-31
RPT Monitoring Unaddressed 2024-10-17
MR Monitoring Resolved 2024-10-01
MR Monitoring Resolved 2024-10-01
MR Monitoring Resolved 2022-07-01
MR Monitoring Resolved 2022-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
26/26 LCR 2025
Bromodichloromethane
13 µg/L
No EPA limit set
worst single sample: 16 µg/L
24/24 SYR4 2012–2019
Chloroform
65.8 µg/L
No EPA limit set
worst single sample: 77 µg/L
24/24 SYR4 2012–2019
TTHM
79.25 µg/L 99%
of the EPA limit 80 µg/L
worst single sample: 87 µg/L
24/24 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
41.55 µg/L 69%
of the EPA limit 60 µg/L
worst single sample: 46 µg/L
24/24 SYR4 2012–2019
Trichloroacetic Acid
29.7 µg/L
No EPA limit set
worst single sample: 32 µg/L
24/24 SYR4 2012–2019
Dichloroacetic Acid
19 µg/L
No EPA limit set
worst single sample: 20 µg/L
21/24 SYR4 2012–2019
Dibromochloromethane
3 µg/L
No EPA limit set
19/24 SYR4 2012–2019
Arsenic
2.76 µg/L 28%
of the EPA limit 10 µg/L
worst single sample: 2.8 µg/L
3/7 SYR4 2012–2019
Barium
52.65 µg/L 2.6%
of the EPA limit 2000 µg/L
worst single sample: 53 µg/L
2/7 SYR4 2012–2019
Chromium
1.376 µg/L 1.4%
of the EPA limit 100 µg/L
worst single sample: 1.4 µg/L
2/7 SYR4 2012–2019
Nitrate
180 µg/L 1.8%
of the EPA limit 10000 µg/L
2/14 SYR4 2012–2019
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBeryllium, TotalBromoformChlorobenzeneCopperCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDibromoacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneFluorideHeptachlorHeptachlor EpoxideLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PLUNKETT, WESLEY
Phone
707-966-1607
Email
WPLUNKETT@SBCGLOBAL.NET

Frequently asked questions about Berryessa Pines Water

Is Berryessa Pines Water tap water safe to drink?

EPA monitoring detected 12 contaminants in Berryessa Pines Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Berryessa Pines Water's water?

EPA monitoring detected Lead, Bromodichloromethane, Chloroform, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Berryessa Pines Water serve?

Berryessa Pines Water reports serving 261 people in California, per its EPA record.

Has Berryessa Pines Water had any water quality violations?

The EPA has 29 violations on file for Berryessa Pines Water, of which 5 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.