← California

Tap water quality report

Chetmoore Acres Wa

EPA monitoring tested this supplier for 41 contaminants and detected 4. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

41
contaminants tested
4
detected
59
people served
14
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Monterey

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

14
health-based violations
30
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2010-10-01 → 2010-10-31
MCL Health-based Resolved 2010-10-01 → 2010-10-31
MCL Health-based Resolved 2008-03-01 → 2008-03-31
MCL Health-based Resolved 2008-03-01 → 2008-03-31
MCL Health-based Resolved 2008-03-01 → 2008-03-31
MCL Health-based Resolved 2008-01-01 → 2008-01-31
MCL Health-based Resolved 2008-01-01 → 2008-01-31
MCL Health-based Resolved 2008-01-01 → 2008-01-31
MCL Health-based Resolved 2003-12-01 → 2003-12-31
MCL Health-based Resolved 2003-12-01 → 2003-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
5800 µg/L 58%
of the EPA limit 10000 µg/L
48/48 SYR4 2012–2019
Lead
0.0023 mg/L 15%
of the EPA limit 0.0150 mg/L
5/5 LCR 2025
Nitrate-Nitrite
2400 µg/L 24%
of the EPA limit 10000 µg/L
1/1 SYR4 2016
Nitrite
0.3000 µg/L 0%
of the EPA limit 1000 µg/L
1/2 SYR4 2016–2019
37 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAsbestosAtrazineBenzeneBenzo(A)PyreneChlorobenzeneCarbofuranCarbon TetrachlorideDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylbenzeneLassoOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
AGUIRRE, BELEN
Phone
831-840-0725
Email
chetmoorewater@gmail.com

Frequently asked questions about Chetmoore Acres Wa

Is Chetmoore Acres Wa tap water safe to drink?

EPA monitoring detected 4 contaminants in Chetmoore Acres Wa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Chetmoore Acres Wa's water?

EPA monitoring detected Nitrate, Lead, Nitrate-Nitrite, Nitrite. The full list with the level and data source for each is above.

How many people does Chetmoore Acres Wa serve?

Chetmoore Acres Wa reports serving 59 people in California, per its EPA record.

Has Chetmoore Acres Wa had any water quality violations?

The EPA has 30 violations on file for Chetmoore Acres Wa, of which 14 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.