← California

Tap water quality report

Madera Co sa16 Sumner Hill

EPA monitoring tested this supplier for 57 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

57
contaminants tested
17
detected
135
people served
99
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Madera

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

99
health-based violations
112
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2026-01-01 → 2026-03-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-10-01 → 2025-12-31
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-07-01 → 2025-09-30
MCL Health-based Archived 2025-04-01 → 2025-06-30
MCL Health-based Archived 2025-04-01 → 2025-06-30
MCL Health-based Archived 2025-04-01 → 2025-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Total Haloacetic Acids (HAA5)
204 µg/L 340%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 270 µg/L
27/28 SYR4 2013–2019
Chloroform
180 µg/L
No EPA limit set
worst single sample: 220 µg/L
26/26 SYR4 2014–2019
TTHM
180 µg/L 225%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 230 µg/L
26/26 SYR4 2014–2019
Trichloroacetic Acid
135 µg/L
No EPA limit set
worst single sample: 170 µg/L
26/28 SYR4 2013–2019
Dichloroacetic Acid
70.25 µg/L
No EPA limit set
worst single sample: 96 µg/L
24/26 SYR4 2013–2019
Bromodichloromethane
6.38 µg/L
No EPA limit set
worst single sample: 7.2 µg/L
23/26 SYR4 2014–2019
Monochloroacetic Acid
5.83 µg/L
No EPA limit set
worst single sample: 6 µg/L
18/26 SYR4 2013–2019
Lead
0.0031 mg/L 21%
of the EPA limit 0.0150 mg/L
11/11 LCR 2025
Arsenic
10.555 µg/L 106%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 16 µg/L
10/13 SYR4 2013–2019
Barium
19.1 µg/L 1%
of the EPA limit 2000 µg/L
worst single sample: 20 µg/L
7/10 SYR4 2013–2019
Copper
64.2 µg/L 4.9%
of the EPA limit 1300 µg/L
worst single sample: 68 µg/L
5/10 SYR4 2013–2019
Lead
9.635 µg/L 64%
of the EPA limit 15 µg/L
worst single sample: 11 µg/L
4/8 SYR4 2013–2019
Monobromoacetic Acid
1.57 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
4/26 SYR4 2013–2019
Nitrate
3390 µg/L 34%
of the EPA limit 10000 µg/L
4/34 SYR4 2012–2019
Chromium
2.35 µg/L 2.4%
of the EPA limit 100 µg/L
worst single sample: 2.4 µg/L
2/10 SYR4 2013–2019
Dibromoacetic Acid
3.3 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
2/26 SYR4 2013–2019
Fluoride
120 µg/L 3%
of the EPA limit 4000 µg/L
1/10 SYR4 2013–2019
40 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalAsbestosAtrazineBenzeneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideCombined Radium (-226 And -228)Combined UraniumDichloromethaneDibromochloromethaneEthylene DibromideEndothallEthylbenzeneLassoMercuryNitriteSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TOLER, PHIL
Phone
559-675-7811
Email
philip.toler@maderacounty.com

Frequently asked questions about Madera Co sa16 Sumner Hill

Is Madera Co sa16 Sumner Hill tap water safe to drink?

EPA monitoring detected 17 contaminants in Madera Co sa16 Sumner Hill's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Madera Co sa16 Sumner Hill's water?

EPA monitoring detected Total Haloacetic Acids (HAA5), Chloroform, TTHM, Trichloroacetic Acid, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Madera Co sa16 Sumner Hill serve?

Madera Co sa16 Sumner Hill reports serving 135 people in California, per its EPA record.

Has Madera Co sa16 Sumner Hill had any water quality violations?

The EPA has 112 violations on file for Madera Co sa16 Sumner Hill, of which 99 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.