EPA monitoring tested this supplier for 81 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
21
detected
0
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Los Angeles

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
1
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 1992-07-01 → 2000-03-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
17628 µg/L 176%
of the EPA limit, in the worst sample — 10000 µg/L
2744/2744 SYR4 2012–2019
Trichloroethylene
57 µg/L 1140%
of the EPA limit, in the worst sample — 5 µg/L
2517/2820 SYR4 2012–2019
Tetrachloroethylene
58 µg/L 1160%
of the EPA limit, in the worst sample — 5 µg/L
1892/2820 SYR4 2012–2019
Carbon Tetrachloride
3.2 µg/L 64%
of the EPA limit 5 µg/L
681/2775 SYR4 2012–2019
1,1-Dichloroethylene
9.4 µg/L 134%
of the EPA limit, in the worst sample — 7 µg/L
417/650 SYR4 2012–2019
Arsenic
7.6 µg/L 76%
of the EPA limit 10 µg/L
368/700 SYR4 2012–2019
cis-1,2-Dichloroethylene
6.5 µg/L 9.3%
of the EPA limit 70 µg/L
190/340 SYR4 2012–2019
Fluoride
380 µg/L 9.5%
of the EPA limit 4000 µg/L
135/135 SYR4 2012–2019
Barium
210 µg/L 11%
of the EPA limit 2000 µg/L
134/135 SYR4 2012–2019
Nitrate-Nitrite
14000 µg/L 140%
of the EPA limit, in the worst sample — 10000 µg/L
64/64 SYR4 2016–2019
TTHM
25 µg/L 31%
of the EPA limit 80 µg/L
56/95 SYR4 2012–2019
Combined Uranium
6.556 µg/L 22%
of the EPA limit 30 µg/L
14/14 SYR4 2012–2018
Dibromochloromethane
6.9 µg/L
No EPA limit set
13/95 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
10/10 LCR 2013
Total Haloacetic Acids (HAA5)
3.4 µg/L 5.7%
of the EPA limit 60 µg/L
10/95 SYR4 2012–2019
Bromoform
15 µg/L
No EPA limit set
8/95 SYR4 2012–2019
Dichloroacetic Acid
1.7 µg/L
No EPA limit set
7/95 SYR4 2012–2019
trans-1,2-Dichloroethylene
7 µg/L 7%
of the EPA limit 100 µg/L
5/178 SYR4 2012–2019
Bromodichloromethane
2.3 µg/L
No EPA limit set
4/95 SYR4 2012–2019
Dibromoacetic Acid
3.4 µg/L
No EPA limit set
3/95 SYR4 2012–2019
1,2-Dichloroethane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/1020 SYR4 2012–2019
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbofuranChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidVinyl ChlorideXylenes, TotalO-DichlorobenzeneP-Dichlorobenzene

Utility contact

Contact
NORIEGA, LYNDA
Phone
562-947-3811
Email
LNORIEGA@CALDOMESTIC.COM

Frequently asked questions about California Domestic Water Company

Is California Domestic Water Company tap water safe to drink?

EPA monitoring detected 21 contaminants in California Domestic Water Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in California Domestic Water Company's water?

EPA monitoring detected Nitrate, Trichloroethylene, Tetrachloroethylene, Carbon Tetrachloride, 1,1-Dichloroethylene, and others. The full list with the level and data source for each is above.

How many people does California Domestic Water Company serve?

California Domestic Water Company reports serving 0 people in California, per its EPA record.

Has California Domestic Water Company had any water quality violations?

The EPA has 1 violation on file for California Domestic Water Company, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.