← California

Tap water quality report

Lynwood Park Mutual Water Co.

EPA monitoring tested this supplier for 56 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

56
contaminants tested
18
detected
1,500
people served
16
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Los Angeles

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

16
health-based violations
26
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2018-05-01 → 2018-05-31
MCL Health-based Resolved 2018-05-01 → 2018-05-31
TT Health-based Resolved 2017-11-01
TT Health-based Resolved 2017-11-01
MCL Health-based Resolved 2013-08-01 → 2013-08-31
MCL Health-based Resolved 2013-08-01 → 2013-08-31
MCL Health-based Resolved 2000-01-01 → 2000-01-31
MCL Health-based Resolved 2000-01-01 → 2000-01-31
MCL Health-based Resolved 1997-01-01 → 1997-01-31
MCL Health-based Resolved 1997-01-01 → 1997-01-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Tetrachloroethylene
5.4 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 6.5 µg/L
132/133 SYR4 2012–2019
Nitrate
1700 µg/L 17%
of the EPA limit 10000 µg/L
worst single sample: 1900 µg/L
52/52 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
15/15 LCR 2023
TTHM
13.47 µg/L 17%
of the EPA limit 80 µg/L
worst single sample: 17.1 µg/L
7/39 SYR4 2014–2019
Barium
120 µg/L 6%
of the EPA limit 2000 µg/L
6/6 SYR4 2014–2017
Combined Uranium
7.33825 µg/L 24%
of the EPA limit 30 µg/L
worst single sample: 7.45 µg/L
6/6 SYR4 2013–2018
Fluoride
377.5 µg/L 9.4%
of the EPA limit 4000 µg/L
worst single sample: 380 µg/L
6/6 SYR4 2014–2017
Dibromochloromethane
2.36 µg/L
No EPA limit set
worst single sample: 2.6 µg/L
5/39 SYR4 2014–2019
Bromodichloromethane
3.71 µg/L
No EPA limit set
worst single sample: 4.1 µg/L
4/39 SYR4 2014–2019
Chloroform
9.185 µg/L
No EPA limit set
worst single sample: 10.4 µg/L
4/39 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
3.495 µg/L 5.8%
of the EPA limit 60 µg/L
worst single sample: 3.9 µg/L
4/39 SYR4 2014–2019
Arsenic
3.27 µg/L 33%
of the EPA limit 10 µg/L
worst single sample: 3.3 µg/L
3/6 SYR4 2014–2017
Bromoform
1.7 µg/L
No EPA limit set
2/39 SYR4 2014–2019
Dichloroacetic Acid
2.15 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
2/39 SYR4 2014–2019
Trichloroacetic Acid
1.665 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
2/39 SYR4 2014–2019
Dibromoacetic Acid
1.1 µg/L
No EPA limit set
1/39 SYR4 2014–2019
Ethylbenzene
0.7600 µg/L 0.1%
of the EPA limit 700 µg/L
1/94 SYR4 2012–2019
Xylenes, Total
3.6 µg/L 0%
of the EPA limit 10000 µg/L
1/91 SYR4 2012–2019
38 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalAsbestosAtrazineBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateLassoLeadMercuryMonobromoacetic AcidMonochloroacetic AcidNitriteSeleniumSimazineStyreneThallium, TotalTolueneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MEZA, JUANITA
Phone
310-631-2625
Email
mutualwatercompany2644@gmail.com

Frequently asked questions about Lynwood Park Mutual Water Co.

Is Lynwood Park Mutual Water Co. tap water safe to drink?

EPA monitoring detected 18 contaminants in Lynwood Park Mutual Water Co.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lynwood Park Mutual Water Co.'s water?

EPA monitoring detected Tetrachloroethylene, Nitrate, Lead, TTHM, Barium, and others. The full list with the level and data source for each is above.

How many people does Lynwood Park Mutual Water Co. serve?

Lynwood Park Mutual Water Co. reports serving 1,500 people in California, per its EPA record.

Has Lynwood Park Mutual Water Co. had any water quality violations?

The EPA has 26 violations on file for Lynwood Park Mutual Water Co., of which 16 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.