Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 1993-06-01 → 1993-10-31 |
| TT | Health-based | Resolved | 1993-06-01 → 1993-10-31 |
| TT | Health-based | Resolved | 1993-06-01 → 1993-10-31 |
| TT | Health-based | Resolved | 1993-06-01 → 1993-10-31 |
| MON | Monitoring | Resolved | 2019-08-01 → 2019-08-31 |
| MON | Monitoring | Resolved | 2019-08-01 → 2019-08-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 20000 µg/L 200% of the EPA limit, in the worst sample — 10000 µg/L | 3268/3290 | SYR4 | 2012–2019 |
| Tetrachloroethylene | 260 µg/L 5200% of the EPA limit, in the worst sample — 5 µg/L | 719/5273 | SYR4 | 2012–2019 |
| Trichloroethylene | 76 µg/L 1520% of the EPA limit, in the worst sample — 5 µg/L | 619/5273 | SYR4 | 2012–2019 |
| TTHM | 27 µg/L 34% of the EPA limit 80 µg/L | 213/2877 | SYR4 | 2012–2019 |
| 1,1-Dichloroethylene | 13 µg/L 186% of the EPA limit, in the worst sample — 7 µg/L | 175/5243 | SYR4 | 2012–2019 |
| cis-1,2-Dichloroethylene | 7.8 µg/L 11% of the EPA limit 70 µg/L | 146/5243 | SYR4 | 2012–2019 |
| Dibromochloromethane | 2.5 µg/L No EPA limit set | 86/4901 | SYR4 | 2012–2019 |
| Bromoform | 4.3 µg/L No EPA limit set | 54/4901 | SYR4 | 2012–2019 |
| Chloroform | 27 µg/L No EPA limit set | 48/4901 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 39/39 | LCR | 2023 |
| Barium | 230 µg/L 12% of the EPA limit 2000 µg/L | 28/28 | SYR4 | 2012–2019 |
| Fluoride | 310 µg/L 7.8% of the EPA limit 4000 µg/L | 28/28 | SYR4 | 2012–2019 |
| Bromodichloromethane | 1.7 µg/L No EPA limit set | 19/4901 | SYR4 | 2012–2019 |
| Arsenic | 2.1 µg/L 21% of the EPA limit 10 µg/L | 12/28 | SYR4 | 2012–2019 |
| Carbon Tetrachloride | 0.8900 µg/L 18% of the EPA limit 5 µg/L | 11/5188 | SYR4 | 2012–2019 |
| Dichloromethane | 2 µg/L 40% of the EPA limit 5 µg/L | 9/5188 | SYR4 | 2012–2019 |
| Combined Uranium | 8.642 µg/L 29% of the EPA limit 30 µg/L | 6/6 | SYR4 | 2014–2017 |
| Dibromoacetic Acid | 2.3 µg/L No EPA limit set | 6/256 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 20000 µg/L 200% of the EPA limit, in the worst sample — 10000 µg/L | 6/6 | SYR4 | 2017–2018 |
| Total Haloacetic Acids (HAA5) | 2.3 µg/L 3.8% of the EPA limit 60 µg/L | 6/256 | SYR4 | 2012–2019 |
| trans-1,2-Dichloroethylene | 12 µg/L 12% of the EPA limit 100 µg/L | 3/5188 | SYR4 | 2012–2019 |
62 contaminants tested, none detected
Utility contact
Frequently asked questions about Valley County Water Dist.
Is Valley County Water Dist. tap water safe to drink?
EPA monitoring detected 21 contaminants in Valley County Water Dist.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Valley County Water Dist.'s water?
EPA monitoring detected Nitrate, Tetrachloroethylene, Trichloroethylene, TTHM, 1,1-Dichloroethylene, and others. The full list with the level and data source for each is above.
How many people does Valley County Water Dist. serve?
Valley County Water Dist. reports serving 68,871 people in California, per its EPA record.
Has Valley County Water Dist. had any water quality violations?
The EPA has 6 violations on file for Valley County Water Dist., of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.