← California

Tap water quality report

West Kern Water District

EPA monitoring tested this supplier for 110 contaminants and detected 29. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

110
contaminants tested
29
detected
20,500
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Kern

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
3
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2011-01-01
MR Monitoring Resolved 2011-01-01
MR Monitoring Resolved 2005-01-01 → 2005-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Arsenic
13 µg/L 130%
of the EPA limit, at the 95th percentile of samples — 10 µg/L
worst single sample: 23 µg/L
681/1240 SYR4 2012–2019
Nitrate
6097.8 µg/L 61%
of the EPA limit 10000 µg/L
worst single sample: 6780 µg/L
228/242 SYR4 2012–2019
Combined Uranium
31.29 µg/L 104%
of the EPA limit, at the 95th percentile of samples — 30 µg/L
worst single sample: 34.27 µg/L
41/42 SYR4 2012–2019
Barium
62.2 µg/L 3.1%
of the EPA limit 2000 µg/L
worst single sample: 103 µg/L
29/46 SYR4 2012–2019
Fluoride
337.2 µg/L 8.4%
of the EPA limit 4000 µg/L
worst single sample: 440 µg/L
29/41 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
26/26 LCR 2024
Antimony, Total
10.75 µg/L 179%
of the EPA limit, at the 95th percentile of samples — 6 µg/L
worst single sample: 22 µg/L
16/83 SYR4 2012–2019
Bromoform
24 µg/L
No EPA limit set
worst single sample: 27 µg/L
16/16 SYR4 2013–2019
Dibromoacetic Acid
4.025 µg/L
No EPA limit set
worst single sample: 4.4 µg/L
16/16 SYR4 2013–2019
Dibromochloromethane
5.5 µg/L
No EPA limit set
worst single sample: 6.1 µg/L
16/16 SYR4 2013–2019
TTHM
28 µg/L 35%
of the EPA limit 80 µg/L
worst single sample: 34 µg/L
16/16 SYR4 2013–2019
Nitrate-Nitrite
953000 µg/L 9530%
of the EPA limit, at the 95th percentile of samples — 10000 µg/L
worst single sample: 960000 µg/L
15/17 SYR4 2013–2019
Lead
11.175 µg/L 75%
of the EPA limit 15 µg/L
worst single sample: 19.3 µg/L
14/64 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
4.34 µg/L 7.2%
of the EPA limit 60 µg/L
worst single sample: 4.4 µg/L
13/16 SYR4 2013–2019
Gross Beta Particle Activity
7.64 pCi/L
No EPA limit set
worst single sample: 8.2 pCi/L
8/10 SYR4 2012–2019
Bromodichloromethane
1.37 µg/L
No EPA limit set
worst single sample: 1.4 µg/L
7/16 SYR4 2013–2019
Chromium
3.46 µg/L 3.5%
of the EPA limit 100 µg/L
worst single sample: 4 µg/L
7/51 SYR4 2012–2019
Combined Radium (-226 And -228)
0.3295 pCi/L 6.6%
of the EPA limit 5 pCi/L
worst single sample: 0.3430 pCi/L
7/7 SYR4 2019
Selenium
6.75 µg/L 14%
of the EPA limit 50 µg/L
worst single sample: 7 µg/L
6/41 SYR4 2012–2019
Copper
33.8 µg/L 2.6%
of the EPA limit 1300 µg/L
worst single sample: 39 µg/L
5/41 SYR4 2012–2019
Nitrite
2.75 µg/L 0.3%
of the EPA limit 1000 µg/L
worst single sample: 2.82 µg/L
5/46 SYR4 2012–2019
Thallium, Total
7.3 µg/L 365%
of the EPA limit, at the 95th percentile of samples — 2 µg/L
worst single sample: 8 µg/L
3/42 SYR4 2012–2019
Chlorobenzene
2.525 µg/L 2.5%
of the EPA limit 100 µg/L
worst single sample: 2.6 µg/L
2/48 SYR4 2012–2019
Mercury
1 µg/L 50%
of the EPA limit 2 µg/L
2/41 SYR4 2012–2019
Trichloroacetic Acid
1.695 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
2/16 SYR4 2013–2019
Cadmium
1 µg/L 20%
of the EPA limit 5 µg/L
1/46 SYR4 2012–2019
Ethylbenzene
1.4 µg/L 0.2%
of the EPA limit 700 µg/L
1/48 SYR4 2012–2019
Styrene
2.1 µg/L 2.1%
of the EPA limit 100 µg/L
1/48 SYR4 2012–2019
Xylenes, Total
1 µg/L 0%
of the EPA limit 10000 µg/L
1/48 SYR4 2012–2019
81 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalCyanideCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEthylene DibromideEndothallEndrinHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ADAMS-ROSENBERGER, WENDY
Phone
661-763-3151
Email
wendy@wkwd.org

Frequently asked questions about West Kern Water District

Is West Kern Water District tap water safe to drink?

EPA monitoring detected 29 contaminants in West Kern Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in West Kern Water District's water?

EPA monitoring detected Arsenic, Nitrate, Combined Uranium, Barium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does West Kern Water District serve?

West Kern Water District reports serving 20,500 people in California, per its EPA record.

Has West Kern Water District had any water quality violations?

The EPA has 3 violations on file for West Kern Water District, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.