← California

Tap water quality report

Tradewind Water Assoc.

EPA monitoring tested this supplier for 52 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

52
contaminants tested
16
detected
632
people served
47
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Kern

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

47
health-based violations
74
violations on file
2
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-04-01 → 2025-06-30
MCL Health-based Resolved 2025-01-01 → 2025-03-31
MCL Health-based Resolved 2025-01-01 → 2025-03-31
TT Health-based Unaddressed 2024-10-17
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-04-01 → 2024-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Combined Uranium
32.78 µg/L 109%
of the EPA limit, at the 95th percentile of samples — 30 µg/L
worst single sample: 34.27 µg/L
55/55 SYR4 2012–2019
Nitrate
2615 µg/L 26%
of the EPA limit 10000 µg/L
worst single sample: 2900 µg/L
40/40 SYR4 2013–2019
Lead
0.0061 mg/L 41%
of the EPA limit 0.0150 mg/L
17/17 LCR 2023
Barium
58.5 µg/L 2.9%
of the EPA limit 2000 µg/L
worst single sample: 60 µg/L
6/6 SYR4 2013–2019
Fluoride
585 µg/L 15%
of the EPA limit 4000 µg/L
worst single sample: 610 µg/L
6/6 SYR4 2013–2019
Bromodichloromethane
2.19 µg/L
No EPA limit set
worst single sample: 2.2 µg/L
3/5 SYR4 2015–2019
Bromoform
6.05 µg/L
No EPA limit set
worst single sample: 6.3 µg/L
3/5 SYR4 2015–2019
Dibromoacetic Acid
2.85 µg/L
No EPA limit set
worst single sample: 2.9 µg/L
3/5 SYR4 2015–2019
Dibromochloromethane
5.73 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
3/5 SYR4 2015–2019
TTHM
14.5 µg/L 18%
of the EPA limit 80 µg/L
worst single sample: 15 µg/L
3/5 SYR4 2015–2019
Total Haloacetic Acids (HAA5)
8.04 µg/L 13%
of the EPA limit 60 µg/L
worst single sample: 8.3 µg/L
3/5 SYR4 2015–2019
Trichloroacetic Acid
6.15 µg/L
No EPA limit set
worst single sample: 6.3 µg/L
2/5 SYR4 2015–2019
1,2-Dichloroethane
0.5000 µg/L 10%
of the EPA limit 5 µg/L
1/4 SYR4 2013–2019
Copper
67 µg/L 5.2%
of the EPA limit 1300 µg/L
1/6 SYR4 2013–2019
Chloroform
0.6400 µg/L
No EPA limit set
1/5 SYR4 2015–2019
Lead
24 µg/L 160%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
1/6 SYR4 2013–2019
36 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DichloropropaneAntimony, TotalArsenicAsbestosAtrazineBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbon TetrachlorideChromiumDichloromethaneDichloroacetic AcidEthylbenzeneLassoMercuryMonobromoacetic AcidMonochloroacetic AcidNitriteSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NAGLE, TATE
Phone
661-205-3205
Email
tradewindswater1@gmail.com

Frequently asked questions about Tradewind Water Assoc.

Is Tradewind Water Assoc. tap water safe to drink?

EPA monitoring detected 16 contaminants in Tradewind Water Assoc.'s water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Tradewind Water Assoc.'s water?

EPA monitoring detected Combined Uranium, Nitrate, Lead, Barium, Fluoride, and others. The full list with the level and data source for each is above.

How many people does Tradewind Water Assoc. serve?

Tradewind Water Assoc. reports serving 632 people in California, per its EPA record.

Has Tradewind Water Assoc. had any water quality violations?

The EPA has 74 violations on file for Tradewind Water Assoc., of which 47 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.