Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2006-07-01 → 2006-07-31 |
| MCL | Health-based | Resolved | 2006-07-01 → 2006-07-31 |
| MCL | Health-based | Resolved | 2006-06-01 → 2006-06-30 |
| MCL | Health-based | Resolved | 2006-06-01 → 2006-06-30 |
| MCL | Health-based | Resolved | 2005-07-01 → 2005-07-31 |
| MCL | Health-based | Resolved | 2005-07-01 → 2005-07-31 |
| MCL | Health-based | Resolved | 2003-05-01 → 2003-05-31 |
| MCL | Health-based | Resolved | 2003-05-01 → 2003-05-31 |
| MR | Monitoring | Resolved | 2020-10-01 |
| MR | Monitoring | Resolved | 2020-10-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 1283.79 µg/L 13% of the EPA limit 10000 µg/L
worst single sample: 1288.2 µg/L | 22/22 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 16/16 | LCR | 2023 |
| Barium | 466 µg/L 23% of the EPA limit 2000 µg/L
worst single sample: 468 µg/L | 6/6 | SYR4 | 2012–2019 |
| Toluene | 16.34 µg/L 1.6% of the EPA limit 1000 µg/L
worst single sample: 18 µg/L | 3/9 | SYR4 | 2016–2019 |
| Fluoride | 670.5 µg/L 17% of the EPA limit 4000 µg/L
worst single sample: 700 µg/L | 2/6 | SYR4 | 2012–2019 |
| TTHM | 2.973 µg/L 3.7% of the EPA limit 80 µg/L
worst single sample: 3.1 µg/L | 2/9 | SYR4 | 2014–2018 |
| Arsenic | 2.6 µg/L 26% of the EPA limit 10 µg/L | 1/6 | SYR4 | 2012–2019 |
| Bromodichloromethane | 0.9600 µg/L No EPA limit set | 1/10 | SYR4 | 2014–2018 |
| Copper | 56 µg/L 4.3% of the EPA limit 1300 µg/L | 1/6 | SYR4 | 2012–2019 |
| Chloroform | 1.1 µg/L No EPA limit set | 1/7 | SYR4 | 2014–2018 |
| Chromium | 1.9 µg/L 1.9% of the EPA limit 100 µg/L | 1/6 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 1.6 pCi/L 32% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2016 |
| Combined Uranium | 1.79694 µg/L 6% of the EPA limit 30 µg/L | 1/1 | SYR4 | 2014 |
| Dichloromethane | 11 µg/L 220% of the EPA limit, at the 95th percentile of samples — 5 µg/L | 1/8 | SYR4 | 2016–2018 |
| Dibromochloromethane | 1.1 µg/L No EPA limit set | 1/10 | SYR4 | 2014–2018 |
| Lead | 2.7 µg/L 18% of the EPA limit 15 µg/L | 1/6 | SYR4 | 2014–2019 |
38 contaminants tested, none detected
Utility contact
Frequently asked questions about Cal Fire - Miramonte Conservation Camp
Is Cal Fire - Miramonte Conservation Camp tap water safe to drink?
EPA monitoring detected 16 contaminants in Cal Fire - Miramonte Conservation Camp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Cal Fire - Miramonte Conservation Camp's water?
EPA monitoring detected Nitrate, Lead, Barium, Toluene, Fluoride, and others. The full list with the level and data source for each is above.
How many people does Cal Fire - Miramonte Conservation Camp serve?
Cal Fire - Miramonte Conservation Camp reports serving 52 people in California, per its EPA record.
Has Cal Fire - Miramonte Conservation Camp had any water quality violations?
The EPA has 29 violations on file for Cal Fire - Miramonte Conservation Camp, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.