← California

Tap water quality report

Westside Harvesting

EPA monitoring tested this supplier for 55 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

55
contaminants tested
14
detected
72
people served
60
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Fresno

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

60
health-based violations
87
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
TT Health-based Resolved 2014-02-01 → 2014-02-28
TT Health-based Resolved 2014-02-01 → 2014-02-28
MCL Health-based Resolved 2014-01-01 → 2014-03-31
MCL Health-based Resolved 2014-01-01 → 2014-03-31
MCL Health-based Resolved 2013-10-01 → 2013-12-31
MCL Health-based Resolved 2013-10-01 → 2013-12-31
MCL Health-based Resolved 2013-07-01 → 2013-09-30
MCL Health-based Resolved 2013-07-01 → 2013-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
47.3 µg/L
No EPA limit set
worst single sample: 63 µg/L
28/28 SYR4 2012–2019
Chloroform
44.65 µg/L
No EPA limit set
worst single sample: 61 µg/L
28/28 SYR4 2012–2019
Dibromochloromethane
68.65 µg/L
No EPA limit set
worst single sample: 80 µg/L
28/28 SYR4 2012–2019
TTHM
180 µg/L 225%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 230 µg/L
28/28 SYR4 2012–2019
Dichloroacetic Acid
30.1 µg/L
No EPA limit set
worst single sample: 44 µg/L
27/28 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
77.6 µg/L 129%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 110 µg/L
27/28 SYR4 2012–2019
Trichloroacetic Acid
28.1 µg/L
No EPA limit set
worst single sample: 68 µg/L
27/28 SYR4 2012–2019
Dibromoacetic Acid
22.5 µg/L
No EPA limit set
worst single sample: 26 µg/L
26/28 SYR4 2012–2019
Bromoform
36.8 µg/L
No EPA limit set
worst single sample: 42 µg/L
23/28 SYR4 2012–2019
Monobromoacetic Acid
2.79 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
18/28 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2026
Monochloroacetic Acid
4 µg/L
No EPA limit set
7/28 SYR4 2012–2019
Nitrate
542.4 µg/L 5.4%
of the EPA limit 10000 µg/L
4/16 SYR4 2012–2019
Fluoride
110 µg/L 2.8%
of the EPA limit 4000 µg/L
2/8 SYR4 2012–2019
41 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicAsbestosAtrazineBariumBenzeneBeryllium, TotalChlorobenzeneCopperCadmiumCarbon TetrachlorideChromiumDichloromethaneEthylene DibromideEndothallEthylbenzeneLassoLeadMercuryNitrate-NitriteNitriteSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
HANNAH, MIKE
Phone
559-285-1071
Email
mikehannah@att.net

Frequently asked questions about Westside Harvesting

Is Westside Harvesting tap water safe to drink?

EPA monitoring detected 14 contaminants in Westside Harvesting's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Westside Harvesting's water?

EPA monitoring detected Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Westside Harvesting serve?

Westside Harvesting reports serving 72 people in California, per its EPA record.

Has Westside Harvesting had any water quality violations?

The EPA has 87 violations on file for Westside Harvesting, of which 60 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.