← California

Tap water quality report

Britz/Colusa

EPA monitoring tested this supplier for 54 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

54
contaminants tested
16
detected
85
people served
33
health-based violations
Water source
Surface water
Ownership
Private
Counties served
Fresno

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

33
health-based violations
62
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2016-04-01 → 2016-06-30
MCL Health-based Resolved 2016-04-01 → 2016-06-30
MCL Health-based Resolved 2016-01-01 → 2016-03-31
MCL Health-based Resolved 2016-01-01 → 2016-03-31
MCL Health-based Resolved 2015-10-01 → 2015-12-31
MCL Health-based Resolved 2015-10-01 → 2015-12-31
MCL Health-based Resolved 2015-07-01 → 2015-09-30
MCL Health-based Resolved 2015-07-01 → 2015-09-30
MCL Health-based Resolved 2015-04-01 → 2015-06-30
MCL Health-based Resolved 2015-04-01 → 2015-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Bromodichloromethane
35.8 µg/L
No EPA limit set
worst single sample: 54 µg/L
25/25 SYR4 2013–2019
TTHM
142 µg/L 178%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 190 µg/L
25/25 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
34.4 µg/L 57%
of the EPA limit 60 µg/L
worst single sample: 47 µg/L
25/25 SYR4 2013–2019
Chloroform
13.85 µg/L
No EPA limit set
worst single sample: 22 µg/L
24/25 SYR4 2013–2019
Dibromoacetic Acid
26.4 µg/L
No EPA limit set
worst single sample: 28 µg/L
24/25 SYR4 2013–2019
Dibromochloromethane
62.2 µg/L
No EPA limit set
worst single sample: 81 µg/L
24/25 SYR4 2013–2019
Dichloroacetic Acid
10.685 µg/L
No EPA limit set
worst single sample: 17 µg/L
24/25 SYR4 2013–2019
Bromoform
46.1 µg/L
No EPA limit set
worst single sample: 48 µg/L
20/25 SYR4 2013–2019
Trichloroacetic Acid
7.66 µg/L
No EPA limit set
worst single sample: 9.1 µg/L
19/25 SYR4 2013–2019
Nitrate
1808 µg/L 18%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Monobromoacetic Acid
2.72 µg/L
No EPA limit set
worst single sample: 2.9 µg/L
13/25 SYR4 2013–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
12/12 LCR 2023
Arsenic
2.48 µg/L 25%
of the EPA limit 10 µg/L
worst single sample: 2.5 µg/L
3/8 SYR4 2012–2019
Fluoride
110 µg/L 2.8%
of the EPA limit 4000 µg/L
3/8 SYR4 2012–2019
Nitrate-Nitrite
976 µg/L 9.8%
of the EPA limit 10000 µg/L
worst single sample: 1000 µg/L
3/3 SYR4 2017–2019
Monochloroacetic Acid
2.5 µg/L
No EPA limit set
1/25 SYR4 2013–2019
38 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalAsbestosAtrazineBariumBenzeneBeryllium, TotalChlorobenzeneCopperCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneEndothallEthylbenzeneLassoLeadMercuryNitriteSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SAGARIBALLA, JOEY
Phone
559-448-8000
Email
joeys@britzinc.com

Frequently asked questions about Britz/Colusa

Is Britz/Colusa tap water safe to drink?

EPA monitoring detected 16 contaminants in Britz/Colusa's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Britz/Colusa's water?

EPA monitoring detected Bromodichloromethane, TTHM, Total Haloacetic Acids (HAA5), Chloroform, Dibromoacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Britz/Colusa serve?

Britz/Colusa reports serving 85 people in California, per its EPA record.

Has Britz/Colusa had any water quality violations?

The EPA has 62 violations on file for Britz/Colusa, of which 33 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.