Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 1995-03-01 → 1995-03-31 |
| TT | Health-based | Resolved | 1995-03-01 → 1995-03-31 |
| TT | Health-based | Resolved | 1995-03-01 → 1995-03-31 |
| Other | Monitoring | Archived | 1987-08-01 → 1987-08-31 |
| Other | Monitoring | Archived | 1987-07-01 → 1987-07-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Chloroform | 85 µg/L No EPA limit set | 48/55 | SYR4 | 2012–2019 |
| TTHM | 91 µg/L 114% of the EPA limit, in the worst sample — 80 µg/L | 48/55 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 94 µg/L 157% of the EPA limit, in the worst sample — 60 µg/L | 48/48 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 53 µg/L No EPA limit set | 48/48 | SYR4 | 2013–2019 |
| Bromodichloromethane | 23 µg/L No EPA limit set | 46/55 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 39 µg/L No EPA limit set | 46/48 | SYR4 | 2013–2019 |
| Lead | 0.0018 mg/L 12% of the EPA limit 0.0150 mg/L | 34/34 | LCR | 2024 |
| Bromate | 3.6 µg/L 36% of the EPA limit 10 µg/L | 12/79 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 5.9 µg/L No EPA limit set | 12/52 | SYR4 | 2013–2019 |
| Nitrate | 131.08 µg/L 1.3% of the EPA limit 10000 µg/L | 12/32 | SYR4 | 2012–2019 |
| Bromoform | 12 µg/L No EPA limit set | 6/59 | SYR4 | 2012–2019 |
| Dibromochloromethane | 3 µg/L No EPA limit set | 6/59 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 130000 µg/L 1300% of the EPA limit, in the worst sample — 10000 µg/L | 6/14 | SYR4 | 2012–2019 |
| Fluoride | 110 µg/L 2.8% of the EPA limit 4000 µg/L | 3/16 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1 µg/L No EPA limit set | 2/52 | SYR4 | 2013–2019 |
| Asbestos | 0.1900 MFL 2.7% of the EPA limit 7 MFL | 1/2 | SYR4 | 2013–2017 |
| Dibromoacetic Acid | 1 µg/L No EPA limit set | 1/52 | SYR4 | 2013–2019 |
67 contaminants tested, none detected
Utility contact
Frequently asked questions about Ccwd - Copper Cove
Is Ccwd - Copper Cove tap water safe to drink?
EPA monitoring detected 17 contaminants in Ccwd - Copper Cove's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Ccwd - Copper Cove's water?
EPA monitoring detected Chloroform, TTHM, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Ccwd - Copper Cove serve?
Ccwd - Copper Cove reports serving 5,187 people in California, per its EPA record.
Has Ccwd - Copper Cove had any water quality violations?
The EPA has 5 violations on file for Ccwd - Copper Cove, of which 3 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.