← Arizona

Tap water quality report

Baca Float Water Company

EPA monitoring tested this supplier for 71 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

71
contaminants tested
12
detected
1,090
people served
2
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Santa Cruz

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
77
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2007-10-01 → 2007-12-31
MCL Health-based Resolved 2007-10-01 → 2007-12-31
MR Monitoring Resolved 2024-01-01 → 2024-12-31
MR Monitoring Resolved 2024-01-01 → 2024-12-31
MR Monitoring Resolved 2024-01-01 → 2024-12-31
MR Monitoring Resolved 2024-01-01 → 2024-12-31
MR Monitoring Resolved 2024-01-01 → 2024-12-31
MR Monitoring Resolved 2024-01-01 → 2024-12-31
MR Monitoring Resolved 2024-01-01 → 2024-12-31
MR Monitoring Resolved 2024-01-01 → 2024-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
61 µg/L 4.7%
of the EPA limit 1300 µg/L
39/39 SYR4 2012–2019
Arsenic
9.3 µg/L 93%
of the EPA limit 10 µg/L
33/37 SYR4 2012–2019
Lead
6.9 µg/L 46%
of the EPA limit 15 µg/L
31/40 SYR4 2012–2019
Nitrate
560 µg/L 5.6%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
TTHM
32 µg/L 40%
of the EPA limit 80 µg/L
10/10 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
4.9 µg/L 8.2%
of the EPA limit 60 µg/L
6/10 SYR4 2012–2019
Barium
14 µg/L 0.7%
of the EPA limit 2000 µg/L
3/3 SYR4 2012–2018
Fluoride
1200 µg/L 30%
of the EPA limit 4000 µg/L
3/3 SYR4 2012–2018
Chromium
1.1 µg/L 1.1%
of the EPA limit 100 µg/L
1/3 SYR4 2012–2018
Di(2-ethylhexyl) Phthalate
1.7 µg/L 28%
of the EPA limit 6 µg/L
1/4 SYR4 2014–2019
Nitrate-Nitrite
560 µg/L 5.6%
of the EPA limit 10000 µg/L
1/2 SYR4 2012
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
GAGNE, JASON
Phone
623-935-1100
Email
jgagne@hopewater.com

Frequently asked questions about Baca Float Water Company

Is Baca Float Water Company tap water safe to drink?

EPA monitoring detected 12 contaminants in Baca Float Water Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Baca Float Water Company's water?

EPA monitoring detected Copper, Arsenic, Lead, Nitrate, Lead, and others. The full list with the level and data source for each is above.

How many people does Baca Float Water Company serve?

Baca Float Water Company reports serving 1,090 people in Arizona, per its EPA record.

Has Baca Float Water Company had any water quality violations?

The EPA has 77 violations on file for Baca Float Water Company, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.