← Arizona

Tap water quality report

Gw Farmers Water Co - Continental

EPA monitoring tested this supplier for 101 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

101
contaminants tested
11
detected
5,592
people served
4
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Pima

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

4
health-based violations
142
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2015-07-01 → 2015-07-31
MCL Health-based Resolved 2015-07-01 → 2015-07-31
MCL Health-based Archived 1988-01-01 → 1988-03-31
MCL Health-based Archived 1980-04-07 → 1980-05-06
MR Monitoring Resolved 2024-08-01 → 2024-08-31
MR Monitoring Resolved 2024-08-01 → 2024-08-31
MR Monitoring Resolved 2024-08-01 → 2024-08-31
RPT Monitoring Resolved 2020-12-01
RPT Monitoring Resolved 2020-12-01
RPT Monitoring Resolved 2020-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
160 µg/L 12%
of the EPA limit 1300 µg/L
60/60 SYR4 2013–2019
Nitrate
8700 µg/L 87%
of the EPA limit 10000 µg/L
48/48 SYR4 2012–2019
Lead
2 µg/L 13%
of the EPA limit 15 µg/L
19/60 SYR4 2013–2019
TTHM
8.5 µg/L 11%
of the EPA limit 80 µg/L
12/13 SYR4 2013–2019
Arsenic
5.7 µg/L 57%
of the EPA limit 10 µg/L
7/7 SYR4 2012–2018
Barium
68 µg/L 3.4%
of the EPA limit 2000 µg/L
7/7 SYR4 2012–2018
Fluoride
540 µg/L 14%
of the EPA limit 4000 µg/L
7/7 SYR4 2012–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
6/6 LCR 2025
Lithium
88 µg/L
No EPA limit set
6/6 UCMR-5 2024
Nitrate-Nitrite
4100 µg/L 41%
of the EPA limit 10000 µg/L
3/3 SYR4 2012–2018
Xylenes, Total
2.8 µg/L 0%
of the EPA limit 10000 µg/L
2/17 SYR4 2012–2019
90 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,3,7,8-TCDD2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ARMIJO, SUSAN
Phone
480-328-9281
Email
Susan.Armijo@gwresources.com

Frequently asked questions about Gw Farmers Water Co - Continental

Is Gw Farmers Water Co - Continental tap water safe to drink?

EPA monitoring detected 11 contaminants in Gw Farmers Water Co - Continental's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Gw Farmers Water Co - Continental's water?

EPA monitoring detected Copper, Nitrate, Lead, TTHM, Arsenic, and others. The full list with the level and data source for each is above.

How many people does Gw Farmers Water Co - Continental serve?

Gw Farmers Water Co - Continental reports serving 5,592 people in Arizona, per its EPA record.

Has Gw Farmers Water Co - Continental had any water quality violations?

The EPA has 142 violations on file for Gw Farmers Water Co - Continental, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.