← Arizona

Tap water quality report

Pinetop Water Community Facilities Dist

EPA monitoring tested this supplier for 80 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
15
detected
3,250
people served
2
health-based violations
Water source
Ground water
Ownership
Mixed public/private
Counties served
Navajo

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
423
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2004-08-01 → 2004-08-31
MCL Health-based Resolved 2000-11-01 → 2000-11-30
Other Monitoring Resolved 2025-07-09
Other Monitoring Resolved 2025-07-09
RPT Monitoring Resolved 2024-03-01
RPT Monitoring Resolved 2024-03-01
MR Monitoring Resolved 2023-04-01 → 2023-06-30
MR Monitoring Resolved 2023-04-01 → 2023-06-30
Other Monitoring Resolved 2023-02-19
Other Monitoring Resolved 2023-02-19

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
840 µg/L 8.4%
of the EPA limit 10000 µg/L
76/80 SYR4 2012–2019
Copper
710 µg/L 55%
of the EPA limit 1300 µg/L
28/30 SYR4 2013–2019
Lead
36.2 µg/L 241%
of the EPA limit, in the worst sample — 15 µg/L
14/30 SYR4 2013–2019
TTHM
13.7 µg/L 17%
of the EPA limit 80 µg/L
10/26 SYR4 2012–2019
Barium
290 µg/L 14%
of the EPA limit 2000 µg/L
7/7 SYR4 2013–2019
Lead
0.0100 mg/L 67%
of the EPA limit 0.0150 mg/L
7/7 LCR 2025
Chromium
3.2 µg/L 3.2%
of the EPA limit 100 µg/L
6/7 SYR4 2013–2019
Nitrate-Nitrite
840 µg/L 8.4%
of the EPA limit 10000 µg/L
6/6 SYR4 2012–2016
Arsenic
2.4 µg/L 24%
of the EPA limit 10 µg/L
4/7 SYR4 2013–2019
Combined Radium (-226 And -228)
1.7 pCi/L 34%
of the EPA limit 5 pCi/L
4/7 SYR4 2013–2019
Fluoride
150 µg/L 3.8%
of the EPA limit 4000 µg/L
4/7 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
3.5 µg/L 5.8%
of the EPA limit 60 µg/L
2/26 SYR4 2012–2019
Bromodichloromethane
0.6000 µg/L
No EPA limit set
1/6 SYR4 2019
Bromoform
0.6000 µg/L
No EPA limit set
1/6 SYR4 2019
Dibromochloromethane
0.8000 µg/L
No EPA limit set
1/6 SYR4 2019
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
PINETOP WTR COMM FACILITY DIST
Phone
928-367-2022
Email
smokincook75@gmail.com

Frequently asked questions about Pinetop Water Community Facilities Dist

Is Pinetop Water Community Facilities Dist tap water safe to drink?

EPA monitoring detected 15 contaminants in Pinetop Water Community Facilities Dist's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Pinetop Water Community Facilities Dist's water?

EPA monitoring detected Nitrate, Copper, Lead, TTHM, Barium, and others. The full list with the level and data source for each is above.

How many people does Pinetop Water Community Facilities Dist serve?

Pinetop Water Community Facilities Dist reports serving 3,250 people in Arizona, per its EPA record.

Has Pinetop Water Community Facilities Dist had any water quality violations?

The EPA has 423 violations on file for Pinetop Water Community Facilities Dist, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.