← Arizona

Tap water quality report

Sontel Water Coop

EPA monitoring tested this supplier for 69 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

69
contaminants tested
9
detected
80
people served
5
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Maricopa

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
153
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
TT Health-based Resolved 2024-10-17
Other Monitoring Resolved 2024-12-20
Other Monitoring Resolved 2024-12-20
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17
RPT Monitoring Resolved 2024-10-17

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
7277.5 µg/L 73%
of the EPA limit 10000 µg/L
worst single sample: 8180 µg/L
66/66 SYR4 2012–2019
Copper
129 µg/L 9.9%
of the EPA limit 1300 µg/L
worst single sample: 150 µg/L
15/20 SYR4 2013–2019
Lead
0.00033 mg/L 2.2%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
Lead
38.02 µg/L 253%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 42 µg/L
3/20 SYR4 2013–2019
Nitrate-Nitrite
6758 µg/L 68%
of the EPA limit 10000 µg/L
worst single sample: 6840 µg/L
2/2 SYR4 2012–2015
Arsenic
2.6 µg/L 26%
of the EPA limit 10 µg/L
1/1 SYR4 2012
Barium
39 µg/L 2%
of the EPA limit 2000 µg/L
1/1 SYR4 2012
Chromium
12 µg/L 12%
of the EPA limit 100 µg/L
1/1 SYR4 2012
Fluoride
430 µg/L 11%
of the EPA limit 4000 µg/L
1/1 SYR4 2012
60 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,3,7,8-TCDD2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
SONTEL WELL COOP
Phone
480-773-9632
Email
sontelwell@gmail.com

Frequently asked questions about Sontel Water Coop

Is Sontel Water Coop tap water safe to drink?

EPA monitoring detected 9 contaminants in Sontel Water Coop's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sontel Water Coop's water?

EPA monitoring detected Nitrate, Copper, Lead, Lead, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Sontel Water Coop serve?

Sontel Water Coop reports serving 80 people in Arizona, per its EPA record.

Has Sontel Water Coop had any water quality violations?

The EPA has 153 violations on file for Sontel Water Coop, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.