Compliance record
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1432 µg/L 110% of the EPA limit, at the 95th percentile of samples — 1300 µg/L
worst single sample: 1980 µg/L | 53/80 | SYR4 | 2012–2018 |
| Lead | 5 µg/L 33% of the EPA limit 15 µg/L | 23/83 | SYR4 | 2012–2019 |
| Dibromochloromethane | 3.075 µg/L No EPA limit set
worst single sample: 3.9 µg/L | 12/13 | SYR4 | 2013–2019 |
| Bromodichloromethane | 3.44 µg/L No EPA limit set
worst single sample: 3.8 µg/L | 9/10 | SYR4 | 2014–2019 |
| Chloroform | 4.02 µg/L No EPA limit set
worst single sample: 4.3 µg/L | 9/10 | SYR4 | 2014–2019 |
| Dichloroacetic Acid | 2.295 µg/L No EPA limit set
worst single sample: 2.4 µg/L | 8/8 | SYR4 | 2014–2019 |
| TTHM | 11.63 µg/L 15% of the EPA limit 80 µg/L
worst single sample: 13.1 µg/L | 8/8 | SYR4 | 2014–2019 |
| Total Haloacetic Acids (HAA5) | 6.72 µg/L 11% of the EPA limit 60 µg/L
worst single sample: 7.7 µg/L | 8/8 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 1.57 µg/L No EPA limit set
worst single sample: 1.6 µg/L | 7/8 | SYR4 | 2014–2019 |
| Lead | 0.0030 mg/L 20% of the EPA limit 0.0150 mg/L | 7/7 | LCR | 2002 |
| Trichloroacetic Acid | 1.57 µg/L No EPA limit set
worst single sample: 1.6 µg/L | 7/8 | SYR4 | 2014–2019 |
| Gross Beta Particle Activity | 6.255 pCi/L No EPA limit set
worst single sample: 6.3 pCi/L | 4/4 | SYR4 | 2013–2019 |
| Bromoform | 1.1 µg/L No EPA limit set | 1/10 | SYR4 | 2014–2019 |
| Monobromoacetic Acid | 2.3 µg/L No EPA limit set | 1/8 | SYR4 | 2014–2019 |
63 contaminants tested, none detected
Utility contact
Frequently asked questions about Cleveland Co Rural Water Users Assoc
Is Cleveland Co Rural Water Users Assoc tap water safe to drink?
EPA monitoring detected 14 contaminants in Cleveland Co Rural Water Users Assoc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Cleveland Co Rural Water Users Assoc's water?
EPA monitoring detected Copper, Lead, Dibromochloromethane, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Cleveland Co Rural Water Users Assoc serve?
Cleveland Co Rural Water Users Assoc reports serving 2,244 people in Arkansas, per its EPA record.
Has Cleveland Co Rural Water Users Assoc had any water quality violations?
The EPA has no formal drinking-water violations on file for Cleveland Co Rural Water Users Assoc.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.