Tap water quality report

Camden Water & Sewer Department

EPA monitoring tested this supplier for 104 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
17
detected
4,170
people served
2
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Wilcox

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

2
health-based violations
59
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1997-05-01 → 1997-05-31
MCL Health-based Archived 1997-05-01 → 1997-05-31
MR Monitoring Resolved 2022-01-01 → 2022-12-31
MR Monitoring Resolved 2022-01-01 → 2022-12-31
MR Monitoring Resolved 2022-01-01 → 2022-12-31
MR Monitoring Resolved 2022-01-01 → 2022-12-31
MR Monitoring Resolved 2020-01-01 → 2022-12-31
MR Monitoring Resolved 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31
MR Monitoring Archived 2020-01-01 → 2022-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
215 µg/L 17%
of the EPA limit 1300 µg/L
22/29 SYR4 2013–2019
Lead
0.0380 mg/L 253%
above the EPA limit of 0.0150 mg/L
20/20 LCR 2025
Total Haloacetic Acids (HAA5)
4.8 µg/L 8%
of the EPA limit 60 µg/L
11/16 SYR4 2012–2019
Fluoride
1680 µg/L 42%
of the EPA limit 4000 µg/L
9/9 SYR4 2013–2019
Nitrate
200 µg/L 2%
of the EPA limit 10000 µg/L
6/48 SYR4 2012–2019
Lead
138 µg/L 920%
of the EPA limit, in the worst sample — 15 µg/L
5/29 SYR4 2013–2019
Barium
15 µg/L 0.8%
of the EPA limit 2000 µg/L
4/9 SYR4 2013–2019
Chromium
14.5 µg/L 14%
of the EPA limit 100 µg/L
3/9 SYR4 2013–2019
Selenium
1.8 µg/L 3.6%
of the EPA limit 50 µg/L
3/9 SYR4 2013–2019
Cyanide
23 µg/L 12%
of the EPA limit 200 µg/L
2/9 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
1.1 pCi/L 7.3%
of the EPA limit 15 pCi/L
2/3 SYR4 2016
Nitrate-Nitrite
200 µg/L 2%
of the EPA limit 10000 µg/L
2/9 SYR4 2013–2019
TTHM
10.1 µg/L 13%
of the EPA limit 80 µg/L
2/16 SYR4 2012–2019
Lithium
13.2 µg/L
No EPA limit set
2/2 UCMR-5 2025
Benzo(A)Pyrene
0.3000 µg/L 150%
of the EPA limit, in the worst sample — 0.2000 µg/L
1/18 SYR4 2013–2019
Bromoform
2.42 µg/L
No EPA limit set
1/9 SYR4 2013–2019
Dibromochloromethane
1.05 µg/L
No EPA limit set
1/9 SYR4 2013–2019
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBeryllium, TotalBromodichloromethaneChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CRESWELL, PHIL
Phone
334-682-4603
Email
camdench@frontiernet.net

Frequently asked questions about Camden Water & Sewer Department

Is Camden Water & Sewer Department tap water safe to drink?

EPA monitoring detected 17 contaminants in Camden Water & Sewer Department's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Camden Water & Sewer Department's water?

EPA monitoring detected Copper, Lead, Total Haloacetic Acids (HAA5), Fluoride, Nitrate, and others. The full list with the level and data source for each is above.

How many people does Camden Water & Sewer Department serve?

Camden Water & Sewer Department reports serving 4,170 people in Alabama, per its EPA record.

Has Camden Water & Sewer Department had any water quality violations?

The EPA has 59 violations on file for Camden Water & Sewer Department, of which 2 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.