← Alabama

Tap water quality report

Guin Water & Sewer Board

EPA monitoring tested this supplier for 104 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
12
detected
4,350
people served
17
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Marion

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

17
health-based violations
78
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2011-04-01 → 2011-06-30
MCL Health-based Resolved 2011-04-01 → 2011-06-30
MCL Health-based Resolved 2011-04-01 → 2011-06-30
MCL Health-based Resolved 2011-04-01 → 2011-06-30
MCL Health-based Resolved 2011-01-01 → 2011-03-31
MCL Health-based Resolved 2011-01-01 → 2011-03-31
MCL Health-based Resolved 2011-01-01 → 2011-03-31
MCL Health-based Resolved 2011-01-01 → 2011-03-31
MCL Health-based Archived 2005-07-01 → 2005-07-31
MCL Health-based Archived 1996-10-01 → 1996-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
TTHM
98.5 µg/L 123%
of the EPA limit, in the worst sample — 80 µg/L
146/146 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
91.6 µg/L 153%
of the EPA limit, in the worst sample — 60 µg/L
146/146 SYR4 2012–2019
Copper
193 µg/L 15%
of the EPA limit 1300 µg/L
29/29 SYR4 2012–2019
Lead
0.0021 mg/L 14%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
Barium
41.7 µg/L 2.1%
of the EPA limit 2000 µg/L
8/8 SYR4 2012–2019
Bromodichloromethane
3.5 µg/L
No EPA limit set
8/8 SYR4 2012–2019
Chloroform
34 µg/L
No EPA limit set
8/8 SYR4 2012–2019
Fluoride
1280 µg/L 32%
of the EPA limit 4000 µg/L
6/8 SYR4 2012–2019
Nitrate
370 µg/L 3.7%
of the EPA limit 10000 µg/L
6/18 SYR4 2012–2019
Nitrate-Nitrite
370 µg/L 3.7%
of the EPA limit 10000 µg/L
2/8 SYR4 2012–2019
Chromium
1.32 µg/L 1.3%
of the EPA limit 100 µg/L
1/9 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
2.6 pCi/L 17%
of the EPA limit 15 pCi/L
1/1 SYR4 2016
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoLeadMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RHUDY, KEITH
Phone
205-712-8536
Email
guinwaterplant@gmail.com

Frequently asked questions about Guin Water & Sewer Board

Is Guin Water & Sewer Board tap water safe to drink?

EPA monitoring detected 12 contaminants in Guin Water & Sewer Board's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Guin Water & Sewer Board's water?

EPA monitoring detected TTHM, Total Haloacetic Acids (HAA5), Copper, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Guin Water & Sewer Board serve?

Guin Water & Sewer Board reports serving 4,350 people in Alabama, per its EPA record.

Has Guin Water & Sewer Board had any water quality violations?

The EPA has 78 violations on file for Guin Water & Sewer Board, of which 17 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.