← Alabama

Tap water quality report

Henry County Water Authority

EPA monitoring tested this supplier for 106 contaminants and detected 19. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

106
contaminants tested
19
detected
11,625
people served
7
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Henry

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
632
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2014-10-01 → 2014-12-31
MCL Health-based Resolved 2012-01-01 → 2012-03-31
MCL Health-based Resolved 2012-01-01 → 2012-03-31
MCL Health-based Resolved 2012-01-01 → 2012-03-31
MCL Health-based Resolved 2012-01-01 → 2012-03-31
MR Monitoring Resolved 2025-01-01 → 2025-03-31
MR Monitoring Resolved 2025-01-01 → 2025-03-31
MR Monitoring Resolved 2025-01-01 → 2025-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
240 µg/L 18%
of the EPA limit 1300 µg/L
39/48 SYR4 2013–2019
Nitrate
220 µg/L 2.2%
of the EPA limit 10000 µg/L
30/72 SYR4 2012–2019
TTHM
26.1 µg/L 33%
of the EPA limit 80 µg/L
22/30 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
20/20 LCR 2025
Total Haloacetic Acids (HAA5)
6.47 µg/L 11%
of the EPA limit 60 µg/L
13/30 SYR4 2012–2019
Lead
20 µg/L 133%
of the EPA limit, in the worst sample — 15 µg/L
11/48 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
24 pCi/L 160%
of the EPA limit, in the worst sample — 15 pCi/L
7/9 SYR4 2012–2019
Nitrate-Nitrite
220 µg/L 2.2%
of the EPA limit 10000 µg/L
5/14 SYR4 2013–2019
Barium
18 µg/L 0.9%
of the EPA limit 2000 µg/L
3/16 SYR4 2013–2019
Chloroform
5.6 µg/L
No EPA limit set
3/26 SYR4 2012–2019
Ethylbenzene
0.9400 µg/L 0.1%
of the EPA limit 700 µg/L
3/27 SYR4 2012–2019
Xylenes, Total
4.56 µg/L 0%
of the EPA limit 10000 µg/L
3/27 SYR4 2012–2019
Bromodichloromethane
0.9500 µg/L
No EPA limit set
1/26 SYR4 2012–2019
Bromoform
2.08 µg/L
No EPA limit set
1/26 SYR4 2012–2019
Combined Radium (-226 And -228)
0.5000 pCi/L 10%
of the EPA limit 5 pCi/L
1/1 SYR4 2018
Dichloromethane
1.41 µg/L 28%
of the EPA limit 5 µg/L
1/27 SYR4 2012–2019
Dibromochloromethane
1.9 µg/L
No EPA limit set
1/26 SYR4 2012–2019
Fluoride
620 µg/L 16%
of the EPA limit 4000 µg/L
1/14 SYR4 2013–2019
Gross Beta Particle Activity
4.5 pCi/L
No EPA limit set
1/1 SYR4 2018
87 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TYE, MARK
Phone
334-585-5763
Email
mark.hcwa@comcast.net

Frequently asked questions about Henry County Water Authority

Is Henry County Water Authority tap water safe to drink?

EPA monitoring detected 19 contaminants in Henry County Water Authority's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Henry County Water Authority's water?

EPA monitoring detected Copper, Nitrate, TTHM, Lead, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.

How many people does Henry County Water Authority serve?

Henry County Water Authority reports serving 11,625 people in Alabama, per its EPA record.

Has Henry County Water Authority had any water quality violations?

The EPA has 632 violations on file for Henry County Water Authority, of which 7 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.