← Wisconsin

Tap water quality report

Kenosha, WI

EPA monitoring detected 23 contaminants across the 5 water suppliers serving Kenosha. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

5
water suppliers
99,443
people served
23
contaminants found

What was found in Kenosha's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Fluoride
1111.5 µg/L 28%
of the EPA limit 4000 µg/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
5/5 SYR4
Nitrate
1000 µg/L 10%
of the EPA limit 10000 µg/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
3/5 SYR4
Copper
153.5 µg/L 12%
of the EPA limit 1300 µg/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2017
Highest in the city: 677 µg/L — ELIZABETH MANOR APTS · 30 people · 2018
5/5 SYR4
Nitrate-Nitrite
535.5 µg/L 5.4%
of the EPA limit 10000 µg/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2017
1/5 SYR4
TTHM
47.035 µg/L 59%
of the EPA limit 80 µg/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Chloroform
26 µg/L
No EPA limit set
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
2/5 SYR4
Barium
21.95 µg/L 1.1%
of the EPA limit 2000 µg/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2017
5/5 SYR4
Total Haloacetic Acids (HAA5)
20.545 µg/L 34%
of the EPA limit 60 µg/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Lead
16.25 µg/L 108%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2017
5/5 SYR4
Bromodichloromethane
14 µg/L
No EPA limit set
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Dichloroacetic Acid
10.3 µg/L
No EPA limit set
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Trichloroacetic Acid
10 µg/L
No EPA limit set
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Dibromochloromethane
6.3 µg/L
No EPA limit set
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Styrene
6.23 µg/L 6.2%
of the EPA limit 100 µg/L
Highest in the city: 52ND AVE WATER GROUP · 35 people · 2019
1/5 SYR4
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2014
Highest in the city: 3.692 pCi/L — PLEASANT PRAIRIE MHP · 35 people · 2018
5/5 SYR4
Gross Alpha, Excl. Radon And U
3.6485 pCi/L 24%
of the EPA limit 15 pCi/L
Highest in the city: PLEASANT PRAIRIE MHP · 35 people · 2018
1/5 SYR4
Monochloroacetic Acid
2.97 µg/L
No EPA limit set
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Di(2-ethylhexyl) Phthalate
2.1 µg/L 35%
of the EPA limit 6 µg/L
Highest in the city: ELIZABETH MANOR APTS · 30 people · 2012
1/5 SYR4
Dibromoacetic Acid
1.3 µg/L
No EPA limit set
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Monobromoacetic Acid
1.06 µg/L
No EPA limit set
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Dichloromethane
0.9885 µg/L 20%
of the EPA limit 5 µg/L
Highest in the city: PLEASANT PRAIRIE MHP · 35 people · 2019
1/5 SYR4
Bromoform
0.5980 µg/L
No EPA limit set
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2019
1/5 SYR4
Lead
0.0041 mg/L 27%
of the EPA limit 0.0150 mg/L
Main supplier: KENOSHA WATER UTILITY · 99,218 people · 2025
5/5 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Kenosha

Frequently asked questions about Kenosha tap water

Is Kenosha tap water safe to drink?

EPA testing detected 23 contaminants in the water serving Kenosha. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Kenosha?

5 public water suppliers report drinking-water monitoring for Kenosha, Wisconsin to the EPA. Each is listed above with its population served.

What contaminants are in Kenosha's water?

The contaminants EPA monitoring detected in Kenosha include Fluoride, Nitrate, Copper, Nitrate-Nitrite, TTHM. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.