← Pennsylvania

Tap water quality report

North Wales, PA

EPA monitoring detected 34 contaminants across the 6 water suppliers serving North Wales. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

6
water suppliers
23,513
people served
34
contaminants found

What was found in North Wales's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
8330 µg/L 83%
of the EPA limit 10000 µg/L
6/6 SYR4
Copper
3320 µg/L 255%
of the EPA limit, in the worst sample — 1300 µg/L
6/6 SYR4
Barium
1050 µg/L 53%
of the EPA limit 2000 µg/L
6/6 SYR4
Nitrite
110 µg/L 11%
of the EPA limit 1000 µg/L
1/6 SYR4
Lead
100 µg/L 667%
of the EPA limit, in the worst sample — 15 µg/L
6/6 SYR4
TTHM
74.4 µg/L 93%
of the EPA limit 80 µg/L
6/6 SYR4
Chloroform
58.2 µg/L
No EPA limit set
6/6 SYR4
Combined Uranium
51.84902 µg/L 173%
of the EPA limit, in the worst sample — 30 µg/L
4/6 SYR4
Arsenic
36.4 µg/L 364%
of the EPA limit, in the worst sample — 10 µg/L
6/6 SYR4
Total Haloacetic Acids (HAA5)
26.2 µg/L 44%
of the EPA limit 60 µg/L
6/6 SYR4
Xylenes, Total
21.74 µg/L 0.2%
of the EPA limit 10000 µg/L
1/6 SYR4
Lithium
20.6 µg/L
No EPA limit set
1/6 UCMR-5
Chromium
19.1 µg/L 19%
of the EPA limit 100 µg/L
6/6 SYR4
Bromodichloromethane
17.1 µg/L
No EPA limit set
6/6 SYR4
Dichloroacetic Acid
16.2 µg/L
No EPA limit set
2/6 SYR4
Dibromochloromethane
12.2 µg/L
No EPA limit set
6/6 SYR4
Trichloroacetic Acid
10.6 µg/L
No EPA limit set
4/6 SYR4
Bromoform
8 µg/L
No EPA limit set
6/6 SYR4
Di(2-ethylhexyl) Phthalate
5.32 µg/L 89%
of the EPA limit 6 µg/L
2/6 SYR4
Toluene
3.76 µg/L 0.4%
of the EPA limit 1000 µg/L
1/6 SYR4
Selenium
3.5 µg/L 7%
of the EPA limit 50 µg/L
6/6 SYR4
Ethylbenzene
2.9 µg/L 0.4%
of the EPA limit 700 µg/L
1/6 SYR4
Dibromoacetic Acid
2.12 µg/L
No EPA limit set
2/6 SYR4
Antimony, Total
2 µg/L 33%
of the EPA limit 6 µg/L
2/6 SYR4
Tetrachloroethylene
0.9000 µg/L 18%
of the EPA limit 5 µg/L
1/6 SYR4
1,1-Dichloroethylene
0.3200 µg/L 4.6%
of the EPA limit 7 µg/L
1/6 SYR4
cis-1,2-Dichloroethylene
0.1300 µg/L 0.2%
of the EPA limit 70 µg/L
1/6 SYR4
Benzo(A)Pyrene
0.1200 µg/L 60%
of the EPA limit 0.2000 µg/L
1/6 SYR4
Carbon Tetrachloride
0.1100 µg/L 2.2%
of the EPA limit 5 µg/L
1/6 SYR4
Heptachlor
0.1100 µg/L 27%
of the EPA limit 0.4000 µg/L
1/6 SYR4
Thallium, Total
0.0700 µg/L 3.5%
of the EPA limit 2 µg/L
1/6 SYR4
Mercury
0.0430 µg/L 2.2%
of the EPA limit 2 µg/L
2/6 SYR4
Lead
0.0302 mg/L 201%
above the EPA limit of 0.0150 mg/L
6/6 LCR
Pfba
0.0070 µg/L
No EPA limit set
1/6 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving North Wales

Frequently asked questions about North Wales tap water

Is North Wales tap water safe to drink?

EPA testing detected 34 contaminants in the water serving North Wales. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve North Wales?

6 public water suppliers report drinking-water monitoring for North Wales, Pennsylvania to the EPA. Each is listed above with its population served.

What contaminants are in North Wales's water?

The contaminants EPA monitoring detected in North Wales include Nitrate, Copper, Barium, Nitrite, Lead. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.