← Pennsylvania

Tap water quality report

East Greenville, PA

EPA monitoring detected 26 contaminants across the 3 water suppliers serving East Greenville. A detection doesn't automatically mean the water is unsafe — see the highest level found for each below, with its EPA source and period.

3
water suppliers
10,200
people served
26
contaminants found

What was found in East Greenville's water

The highest level seen across the city's suppliers, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
5430 µg/L 54%
of the EPA limit 10000 µg/L
3/3 SYR4
Barium
600 µg/L 30%
of the EPA limit 2000 µg/L
1/3 SYR4
Copper
582 µg/L 45%
of the EPA limit 1300 µg/L
3/3 SYR4
Total Haloacetic Acids (HAA5)
69 µg/L 115%
of the EPA limit, in the worst sample — 60 µg/L
3/3 SYR4
TTHM
51.9 µg/L 65%
of the EPA limit 80 µg/L
3/3 SYR4
Cyanide
40 µg/L 20%
of the EPA limit 200 µg/L
1/3 SYR4
Chloroform
34.5 µg/L
No EPA limit set
3/3 SYR4
Lead
20 µg/L 133%
of the EPA limit, in the worst sample — 15 µg/L
3/3 SYR4
Lithium
19.9 µg/L
No EPA limit set
1/3 UCMR-5
Bromodichloromethane
14 µg/L
No EPA limit set
3/3 SYR4
Dichloroacetic Acid
13 µg/L
No EPA limit set
1/3 SYR4
Dibromochloromethane
12.2 µg/L
No EPA limit set
3/3 SYR4
Arsenic
11 µg/L 110%
of the EPA limit, in the worst sample — 10 µg/L
3/3 SYR4
Trichloroethylene
10.2 µg/L 204%
of the EPA limit, in the worst sample — 5 µg/L
2/3 SYR4
Trichloroacetic Acid
10 µg/L
No EPA limit set
1/3 SYR4
1,1-Dichloroethylene
7 µg/L 100%
of the EPA limit 7 µg/L
2/3 SYR4
Bromoform
5.7 µg/L
No EPA limit set
3/3 SYR4
Combined Uranium
5.1703 µg/L 17%
of the EPA limit 30 µg/L
2/3 SYR4
Dibromoacetic Acid
3 µg/L
No EPA limit set
1/3 SYR4
Dichloromethane
2.5 µg/L 50%
of the EPA limit 5 µg/L
1/3 SYR4
1,1,1-Trichloroethane
1 µg/L 0.5%
of the EPA limit 200 µg/L
2/3 SYR4
Lead
0.0253 mg/L 169%
above the EPA limit of 0.0150 mg/L
3/3 LCR
PFNA
0.0082 µg/L
No EPA limit set
1/3 UCMR-5
PFOA
0.0062 µg/L
No EPA limit set
1/3 UCMR-5
PFOS
0.0055 µg/L
No EPA limit set
1/3 UCMR-5
PFHXS
0.0030 µg/L
No EPA limit set
1/3 UCMR-5
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the single worst sample on record — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving East Greenville

Frequently asked questions about East Greenville tap water

Is East Greenville tap water safe to drink?

EPA testing detected 26 contaminants in the water serving East Greenville. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve East Greenville?

3 public water suppliers report drinking-water monitoring for East Greenville, Pennsylvania to the EPA. Each is listed above with its population served.

What contaminants are in East Greenville's water?

The contaminants EPA monitoring detected in East Greenville include Nitrate, Barium, Copper, Total Haloacetic Acids (HAA5), TTHM. The full list, with the highest level found and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.